KPF-01
Power harmonic clamp meter
AC Current
Range
2mA-3999mA
4A-200A
Max. allowed overload current: 200 A
Active/apparent power (W/VA)
Range
0.1W/VA-120KW/KVA
Min. test current: 10mA; Min. test voltage: 10V
Power factor
Range
0.3~1 Capacitive
0.3~1 Inductive
Min. test current: 10mA; Min. test voltage: 10V
Passive power
Range
0.1VAr-120KVAr
Min. test current: 10mA; Min. test voltage: 10V
Passive power Var is calculated according to the measured V, A, and kW
value.
Frecuency (Hz)
Range
30Hz~1kHz
Min. test current: 10mA; Min. test voltage: 10V
Instructions manual |
32
Resolution
0.01mA
±(2.0% of reading + 5 digitos)
0.01A
±(2.0% of reading + 5 digitos)
Resolution
0.01W/VA
Resolution
0.001
0.001
Resolution
0.01VAr
Resolution
0.1Hz
Accuracy
Accuracy
±(3.0% of reading + 5 digitos)
Accuracy
±(0.02% of reading + 2 digitos)
±(0.02% of reading + 2 digitos)
Accuracy
±(3.0% of reading + 5 digitos)
Accuracy
±(0.5% of reading + 1 digit)
www.grupotemper.com