DGC-HD
• Observe the required support spacings. The diagrams (
port spacing, which is dependent on the mounting position and effective load. If the specified min-
imum distances are exceeded, it is imperative to carry out an individual functional test.
Note
Unsuitable mounting techniques can damage the DGC-HD.
• Make sure that the mounting components are outside the positioning range of the
slide.
• Fasten the DGC-HD.
• Please select the corresponding accessories from our catalogue (
Profile mounting
MUE
Profile mounting in the slot aA of the mounting
surface 8
Tab. 1
• Tighten the mounting screws uniformly with the following tightening torque.
Size
Screw
MUE
NST (lateral)
NST (underneath)
Tightening torque
MUE
NST (lateral)
NST (underneath)
Tab. 2
Festo – DGC-HD – 1304NH English
12 Characteristic curves) show the sup-
Slot nut mounting
NST
aA
Slot nut mounting in slot aA.
When tilted, the slot nuts slide into the slot at
each position of the profile
18
M5
M5
M5
[Nm]
5
[Nm]
5.9
[Nm]
5.9
www.festo.com/catalogue).
25
40
M5
M8
M5
M6
M6
M6
5
20
5.9
9.9
9.9
9.9