6
InView EtherNet/DeviceNet Module
Publication 2706-IN010C-MU-P
Open the front of the sign case (on 2706-P7x) by turning the
latches to the left. Carefully let the front of the case drop
forward.
Front view, closed
Front view, open
3. Feed the serial cable through the cable grip (shipped with
module).
4. Insert the serial wires through the right conduit opening on
either the top or the bottom of the InView display.
TB1 Terminal Block for serial connection
Power Line
5. Mount the cable grip to the InView display housing. Tighten the
locknut finger-tight and rotate an additional 1/2 turn.
6. Connect the incoming serial wires to the TB1 terminal block.
Brown (Rxd)
Orange (Txd)
Blue (GND)
Quarter-turn latches
Controller board
Insert the serial wires
with the cable grip into
one of these conduit
openings.
TB1
(NC) 8
Incoming
(NC) 7
serial wires
(NC) 6
(NC) 5
(RS-232 RX) 4
(RS-232 TX) 3
(NC) 2
(GND) 1
2706-P72,
2706-P74
POWER
LOAD
GROUND
EARTH
EPROM unit (on
underside of board)
TB1 Terminal Block