Dyna-Glo DGB730SNB Manual De Instrucciones página 22

Ocultar thumbs Ver también para DGB730SNB:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATING INSTRUCTIONS
NOTE: Other cylinders may be acceptable for use with this appliance provided they are compatible
with the appliance nesting hole and retention means. Refer to Step 24 of the Assembly Instructions
for correct cylinder to cylinder holder connection.
ALL INSTRUCTIONS AND SAFEGUARDS ON THIS PAGE MUST BE FOLLOWED TO PREVENT FIRE,
DAMAGE, AND/OR INJURY.
Connecting the LP Tank
1. The knob on the LP tank must be closed. Make sure that the knob is turned clockwise to a full stop.
The cylinder supply system must be arranged for vapor withdrawal.
2. Check that the control knob on the control unit is turned off.
3. Remove the protective cap from the LP tank valve and coupling nut.
4. Hold the regulator in one hand and insert the nipple into the valve outlet.
Be sure the nipple is centered in the valve outlet. The coupling nut
connects to the large outside threads on the valve outlet. Use care – do
not cross thread the connection.
5. Hand-tighten the coupling nut clockwise until it comes to a full stop.
Firmly tighten by hand only. Do not use tools.
To Disconnect: Fully close the tank valve by turning clockwise. Turn the
coupling nut counterclockwise until the regulator assembly detaches.
In the connection process, make sure:
•theregulatorinletconnectormateswiththecylindervalveoutletproperly,safelyandfirmly,and;
•theLPgashosedoesnotcomeincontactorremainincontactwiththefirebox.
WARNING
WARNING
22

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Dgb730snb-d

Tabla de contenido