Connecting The Inlet Hose - KENMORE ELITE 796.6142 Manual De Uso Y Cuidado

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CONNECTING
THE iNLET HOSE
The dryer
must be connected
to the cold water
tap
using the new water
supply
hose. Do not use old hoses,
NOTE:
• Water
supply pressure
must be between
21.8 PSI and
116 PSi (]50_800
kPa).
° Do not strip or cross=thread when connecting
inlet hose
to the valve,
" If the wafer
supply
pressure
is more than 116 PSI (800
kPa), a pressure
reducing
valve should
be installed.
• Periodically
check
the condition of the hose and
replace
the hose if necessary.
• Replace
inlet hoses after 5 years of use to reduce the
risk of hose failure.
• Record
hose insta{lation
or replacement
dotes
on the
hoses for future
reference.
lo Check the rubber seal in the inlet hose. Two rubber
seals are supplied
with each inlet hose. They are used
for preventing water leaks. Make
sure the connection
to the cold water tap is tight.
Rubbzo
I
Y connector
2. Check the installation
type.
I
i_
y" hose
'_Y
connector
__
Long
nose
W_TH WASHER
WITHOUT WASHER
Conned
all wafer
supply hoses tightly
by hand and
then
tlghfen
another
2/3 turn wifh pllers.
WITH
WASHER:
When
connecting the dryer
to the same
faucet
as a washer.
a, Shut off _'he cold water
fop and remove
the washer
hose.
b. Connect the short hose to the Y-connector.
c. Connect
the other
end of the short hose to the cold
wafer fa,acet.
d. Connect the long dryer hose to one side of the Y-connector
and connect
the washer
hose to the other
side,
WITHOUT WASHER: If the dryer does not share the
co{d water tap with a washer.
a. Connect the straight end of the long hose to the cold
water faucet.
NOTE:
• Before connecting the water line to the dryer t flush
several gallons of wafer into a drain or bucket. This
will help prevent foreign particles such as sand and
scale from cloggong
the dryer inlet vane.
• Do not overfighten. Damage to the coupling can
result.
.
Connect the hose to the dryer.
Connect the water supply hose to the dryer inlet
valve tightly by hand and then tighten another 2/3
turn with pliers. Make sure that there are no kinks in
the hoses and that they are not crushed.
4. Turn on the cold water faucet.
5.
Check for leaks at the Y-connector
(if used) and all
hoses.
I
I
NOTE:
" If any leaks are found_ shut off the water faucet,
remove the hose and check the condition of the hose
washer.
16

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

796.7142

Tabla de contenido