Mode Switching Summary
TEST
AUTO
MANUAL MODE
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
D
B
ual
Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). Selecting OFF disables
this feature. The motion sensing features will continue
to work as described in this manual. If motion is sensed,
the light turns on full bright for the ON-TIME (1, 5, or
20 minutes) then returns to dim mode.
INSTALLATION
CAUTION: Keep the sensor at least 2" (51 mm)
away from the bulbs.
CAUTION: To Avoid Fire Or Burn Hazards:
• Allow fixture to cool before touching. The bulb and
the fixture operate at high temperatures.
• Keep fixture at least 2" (51 mm) from combustible
materials. Do not aim at objects closer than 3' (1 m).
• Use only T4 100W (max.), G8 tungsten halogen
bi-pin 120 VAC bulbs.
For easy installation, select an existing light operated
by a wall switch for replacement. IMPORTANT: Do NOT
use with dimmers or timers.
For best performance, mount the fixture about 8 feet
(2.4 m) above the ground. NOTE: If fixture is mounted
higher than 8 feet (2.4 m), aiming the sensor down will
reduce coverage distance.
Move ON-TIME Switch
to 1, 5, or 20 minutes
Flip light switch
off for one second
then back on*
Timer
®
rite
For under eave installation, the sensor head must
be rotated as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.
For eave mount only:
1. Swing the sensor head towards the clamp screw
joint.
Clamp Screw
2. Then rotate the sensor head clockwise 180° so the
controls face down.
If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the ball
joint. Tighten the clamp screw when done.
2
Controls
Controls
Controls
204058-01