Initial Use; Operation; Working Instructions - ULTIMATE SPEED UMK 10 C2 Instrucciones De Utilización Y De Seguridad

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43

Initial use

Place the product on a level, non-flammable
surface. Do not cover the vents. Do not operate
the device in dusty environments. Doing so poses
a fire hazard and could damage the device.
For inflatables with counterpressure (e.g. partly
filled car tyre): Switch on the product before
connecting the connection valve
Note: Depending on the inflatable you can
use the connection valve
with the included valve adapter
Connecting to the cigarette lighter socket:
Note: Verify the socket of the cigarette lighter in
your vehicle has an adequately sized fuse.
Verify the product is switched off: on / off
switch
to position "0".
6
Plug the cigarette lighter plug
of the 12 V cigarette lighter.
Connecting the connection valve
Open the connection valve
lever
vertical (see Fig. B).
8
Connecting without valve adapter
- Insert the open connection valve
valve of the inflatable (if necessary, first remove
valve cover of the inflatable).
- Hold the connection valve and close: push
tensioning lever
8
Connecting with valve adapter
- Push the respective valve adapter into the
opening in the connection valve
- Secure the valve adapter into the connection
valve
: push clamping lever
7
connection valve (see Fig. C).
- Insert the valve adapter
the inflatable (if necessary, first remove valve
cover of the inflatable).
Switching on / off:
Switch the device on: on / off switch
position "I".
to the tyre.
7
directly or along
7
(see Fig. A).
10
into the socket
5
:
7
: clamping
7
:
10
into the
7
toward connection valve
:
10
.
7
toward
8
into the valve on
10
to
6
Once the desired filling pressure has been
reached, switch the device off: on / off
switch
to position "0".
6
Remove the cigarette lighter plug
Removing the connetion valve:
Connecting without valve adapter
the clamping lever
valve
and remove from the valve of the
7
inflatable.
Connecting with valve adapter
valve adapter from the valve of the inflatable.
Open the clamping lever
valve
and remove the valve adapter
7
Note: Air may escape from the valve of the inflat-
able when removing the connection valve
sure not to remove the connection valve
quickly.
The manometer
seek a specialist facility with a calibrated de-
vice after inflating inflatables where incorrect
pressure can be dangerous (e.g. car tyre).

Operation

Working instructions

.
This product is not suitable for continuous operation.
7
It was developed to produce air pressure, not air
volume.
Do not use the product for longer than 5 minutes
without interruption to prevent overheating and
damage to the device. Afterwards allow to
cool for a minimum of 20 minutes.
.
5
: Open
10
for the connection
8
: Remove the
10
of the connection
8
7
too
7
is not calibrated. Therefore
2
GB/IE
.
10
. Be
17

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

298835

Tabla de contenido