DITEC PASAA2 Manual Del Usuario página 7

Ocultar thumbs Ver también para PASAA2:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
Adjustments
1
Presence detection area adjustment
Presence angle adjustment screw
FREQUENCY
PRESENCE
WIRING
SENSITIVITY SELECT SWITCH
GREY
:POWER
TIMER
SUPLLY
2sec.
7sec.
WHITE: COM.
ON
1 2 3 4 5 6 7 8
YELLOW:N.O.
GREEN: N.C.
MOTION OUTOPUT
1 2
1 2
SAFETY
ACTIVATION
WHITE STR. :N.C.
L M H
L M H
OFF
60sec.
GREEN STR.:N.C.
SAFETY OUTOPUT
1 2
1 2
POWER INPUT:
12 to 30V AG/DC
INSTALLATION MODE ON/OFF(FACTORY SETTING:OFF)
POWER CONSUMPTION
: 150MA MAX· (DC12V)
ROW ADJUSTMENT
OUTPUP
SNOW MODE
DEEP(MAX10 )
ACTIVATION :Form C 50V 0.3A MAX.
5ROW
4ROW
3ROW
2ROW
SAFETY:Form B 50V 0.1A MAX. (Both RESISTANCE LOAD)
OPERATION INDICATOR (LEFT)
OPERATION INDICATOR (RIGHT)
GREEN
:STAND-BY
NONE
:STAND-BY
BLINKRED
:1st ROW DETECTION
YELLOW
:INSTALLATION MODE
RED
:2nd ROW DETECTION
SHALLOW(MAX10 )
6 7
6 7
6 7
6 7
ORANGE
:ACTIVATION DETECTION
Prism
1-1
Width detection area adjustment
The width of the detection area can be changed by switching
to the other prism. (Factory setting: Wide prism)
Mounting height
2.20 (7'2 5/8")
2.50 (8'2 7/16")
Wide prism
2.81 (9'2 5/8")
3.20 (10'6")
Narrow prism
1.71 (5'7 5/16")
1.95 (6'4 3/4")
CAUTION
■ The detection area width must be set wider than the threshold.
■ When people enter the door area from the side of the door rather than the front,
the detection area must widen in the direction from which people come in.
Away from the door
1-2 Installation mode selection
With Dipswitch 8 in ON position only the fisrt row of the presence detection area is active.
With Dipswitch 8 in OFF position all the sensor functions are active.
Depth detection area adjustment
1-3
Note:
The PASAA2 is equipped with the possibility to adjust the presence detection area
minus 10° into the threshold. To adjust the minus angle the use of an Infrared finder (like
PASTEST) is recommended. The default setting is 3°.
To adjust the presence detection angle:
1. Remove the protective sticker
2. Switch dipswitch "8" to on. Only the first row of presence detection becomes active
* Door open state
3. Turn the Infrared finder to "on"
4. Place the Infrared finder in the far side of the threshold approximately 5 cm away from
the door wings
5. Turn the presence angle adjustment screw to "deep"
6. Start to turn the presence angle adjustment screw to "shallow" until the Infrared finder
slightly starts to blink and/or beep
PASAA2
ACTIVATION
WIDTH
ADJUSTMENT
PRESENCE AREA
ADJUSTMENT
5724811
SCREW
ACTIVATION
DEEP
ANGLE
ADJUSTMENT
LEFT
RIGHT
SHALLOW
ELIMINATE LEFT ELIMINATE RIGHT
Screw protective sticker
2.70 (8'10 5/16")
3.00 (9'10 1/8")
3.46 (11'4 1/4")
3.84 (12'7 3/16")
2.11 (6'11 1/16")
2.34 (7'8 1/8")
Close to the door
* Operation indicator (right) glows yellow
7. Set dipswitch 8 to "off"
8. Remove all items from the detection area
9. Make a hard reset (switch the power)
10. Step away from the door and wait for approximately 10 seconds
11. Installation is completed
To adjust the presence detection area without the use of the Infrared finder:
Use the procedure as described above but use the PASAA2 LED indicator instead. As long as the LED
continues to blink red their is detection on the first row of presence detection. This can indicate that the
sensor detects the door movement. Turn the presence detection angle screw to "deep".
2
Activation detection area adjustment
WIRING
GREY
:POWER
SUPLLY
WHITE: COM.
1 2 3 4 5 6 7 8
YELLOW:N.O.
GREEN: N.C.
MOTION OUTOPUT
WHITE STR. :N.C.
GREEN STR.:N.C.
SAFETY OUTOPUT
POWER INPUT:
12 to 30V AG/DC
POWER CONSUMPTION
: 150MA MAX· (DC12V)
OUTPUP
ACTIVATION :Form C 50V 0.3A MAX.
SAFETY:Form B 50V 0.1A MAX. (Both RESISTANCE LOAD)
OPERATION INDICATOR (LEFT)
GREEN
:STAND-BY
BLINKRED
:1st ROW DETECTION
RED
:2nd ROW DETECTION
ORANGE
:ACTIVATION DETECTION
Dipswitches
2-1
Width and depth direction adjustment
The area depth can be changed in 3°
The width of the activation detection area (rows 3, 4 and 5) can both be moved at the same time 7° either left or
right in 1 step.
Narrow
Wide
Outside
Door side
2-2
Width detection area adjustment
Use the area adjustment tool to operate the activation width adjustment lever as in the figure on the below.
Activation width
adjustment
lever
1.
Function
All area open
S C R E W
2-3
Depth detection area adjustment
The 5th row, 4th row, and 3rd rows areas can be erased by
combining dipswitches 6 and 7.
* When 2-row setting is selected, only the presence detection area
remains.
5.
6. Beep...Beep...
...Beep...
4.
PASAA2
FREQUENCY
PRESENCE
SENSITIVITY SELECT SWITCH
TIMER
2sec.
7sec.
ON
PRESENCE AREA
1 2
1 2
SAFETY
ACTIVATION
L M H
L M H
ADJUSTMENT
60sec.
OFF
SCREW
1 2
1 2
DEEP
INSTALLATION MODE ON/OFF(FACTORY SETTING:OFF)
LEFT
RIGHT
ROW ADJUSTMENT
SNOW MODE
DEEP(MAX10 )
5ROW
4ROW
3ROW
2ROW
OPERATION INDICATOR (RIGHT)
NONE
:STAND-BY
YELLOW
:INSTALLATION MODE
SHALLOW
SHALLOW(MAX10 )
6 7
6 7
6 7
6 7
Activation angle
adjustment lever
×
2 steps by moving the activation angle adjustment lever up and down.
Right
(direction)
Left (direction)
A
A: Erase
B: Erase
A&B: Erase
ACTIVATION
WIDTH
ADJUSTMENT
5724811
ACTIVATION
ANGLE
ADJUSTMENT
ELIMINATE LEFT ELIMINATE RIGHT
Activation width
adjustment lever
B
A
B
5 rows
4 rows
3 rows
2 rows
6
7
6
7
6
7
6
7

Publicidad

Tabla de contenido
loading

Tabla de contenido