Dipswitch settings
WIRING
FREQUENCY
PRESENCE
GREY
:POWER
TIMER
SUPLLY
2sec.
WHITE: COM.
ON
1 2 3 4 5 6 7 8
YELLOW:N.O.
GREEN: N.C.
MOTION OUTOPUT
1 2
WHITE STR. :N.C.
60sec.
GREEN STR.:N.C.
OFF
SAFETY OUTOPUT
1 2
POWER INPUT:
12 to 30V AG/DC
INSTALLATION MODE ON/OFF(FACTORY SETTING:OFF)
POWER CONSUMPTION
: 150MA MAX· (DC12V)
OUTPUP
SNOW MODE
ACTIVATION :Form C 50V 0.3A MAX.
SAFETY:Form B 50V 0.1A MAX. (Both RESISTANCE LOAD)
OPERATION INDICATOR (LEFT)
OPERATION INDICATOR (RIGHT)
GREEN
:STAND-BY
NONE
:STAND-BY
BLINKRED
:1st ROW DETECTION
YELLOW
:INSTALLATION MODE
RED
:2nd ROW DETECTION
ORANGE
:ACTIVATION DETECTION
1,2 : Presence detection timer
3,4 : Frequency (Interference prevention)
5
: Snow mode
Presence area sensitivity switch
6,7 : Area depth adjustment
8
: Installation mode
3-1
Setting the sensitivity
Set to "M" for regular use. This covers a mounting height up to 3 meters. "H" increases the sensitivity and "L"
lowers the sensitivity.
3-2
Setting the presence detection timer
The 1st and 2nd rows have the presence detection function.
(1) Set the presence detection time with dipswitches 1 and 2.
(2) Turn the power "off", then "on" again and close the door
completely. Wait about 10 seconds with no moving object in
the area. The system is now in the presence detection area
standby state.
Note:
■
Set the presence detection time to at least 15 seconds.
Setting the frequency
3-3
Four different interference prevention modes can be set by
appropriately combining dipswitches 3 and 4.
Note:
When using multiple systems with sensors near each other, set
each to a different position setting.
3-4
Setting the snow mode
In regions where snow almost never falls, use with this set to Normal.
Even with Snow mode set, if there is a large amount of snow, it can trigger detection.
Sensitivity switches
PASAA2
SENSITIVITY SELECT SWITCH
7sec.
PRESENCE AREA
1 2
SAFETY
ACTIVATION
L M H
L M H
ADJUSTMENT
5724811
SCREW
ACTIVATION
1 2
DEEP
ANGLE
ADJUSTMENT
LEFT
RIGHT
ROW ADJUSTMENT
DEEP(MAX10 )
5ROW
4ROW
3ROW
2ROW
SHALLOW
SHALLOW(MAX10 )
6 7
6 7
6 7
6 7
Activation area sensitivity switch
2 seconds
15 seconds
180 seconds
1
2
1
2
1
1
2
3
4
3
4
3
Normal
4
Checking
Follow the flowchart below to check operations.
Entry operation
ACTIVATION
WIDTH
ADJUSTMENT
Status
Operation indicator (left)
ELIMINATE LEFT ELIMINATE RIGHT
Activation
output
PASAA2
Safety
output
Troubleshooting
Explain to the customer
Alarm display
Status
Operation indicator
(left)
1
2
2
Symptom
Does not operate.
Sometimes does not
operate.
Operates on its own
3
4
Replacement
notification
4
3
4
Life cycle Notification
Snow
Saturation display
If the above steps do not solve the problem or if it is necessary to change settings or replace a part, please consult the
5
5
installation contractor.
1
Yellow
2
Green
Outside of
Entry into
Entry into
detection
2nd row
3rd-5th row
area
Standby
Activation detection
Activation and presence detection
Orange
Green
Red
Replacement notification
Life cycle notification
Flashing green blinking
Twice green blinking
Cause of abnormality
Power supply voltage
Open line or connection defect
Detection window dirty
There is a moving object within the detection area.
There is an extremely strong electromagnetic field
or noise generating device near the door.
The header is vibrating
There is water on the detection window.
The sensor is reaching the end of its life cycle or
may be damaged.
A part has reached the end of its service life.
There is a highly reflective object within the
detection area.
DITEC S.p.A.
Via Mons. Banfi, 3 - 21042 Caronno Pertusella (VA) - ITALY
Tel. +39 02 963911 - Fax +39 02 9650314
www.ditec.it - ditec@ditecva.com
3
White
5
Green stripe
4
White stripe
Outside of
Entry into
detection
1st row
area
Standby
Blinking Red
Green
Saturation signal
Slow green blinking
Check point
Set to the stated voltage.
Check the wires and connector.
Clean the detection window.
Move vibrating objects to outside the area.
Fasten the header in place.
Keep water off the detection window.
Contact your installation contractor or the
sales engineer immediately.
Contact your installation contractor or the
sales engineer.
Remove that object.