LEAK TESTING THE REGULATOR, VALVES, HOSES,
AND CONNECTIONS
1. Ensure the LP cylinder valve and burners are
"OFF".
2. Ensure the LP cylinder is connected to the
regulator.
3. Mix up a solution of 50% water and 50% liquid
dish soap. Do not use any household cleaner
solution.
4. Open the LP tank valve by turning the hand wheel
counterclockwise. If you hear a rushing sound,
turn the gas off immediately. In that case, there
could be a leak at the connection. Reconnect the
cylinder to the regulator.
5. Spray or brush on the solution covering the
following areas: cylinder welds, regulator and
cylinder connection, gas hose connection to the
regulator, gas hose, the gas hose connection to the
gas manifold assembly, and the valve connections
to the gas manifold pipe.
6. Growing bubbles on any of the parts and
connections listed above indicate a gas leak.
Immediately shut off the LP tank valve by turning
the valve clockwise. Retighten the connections or
order replacement parts as needed. Continue to
test as necessary until no leaks are detected.
7. Close the LP tank valve after testing by turning
the hand wheel clockwise.
LP Gas Tank
CAUTION
N
ever face your grill opposite the wind direction.
Wind coming from behind the grill may make lid
handle hot to touch.
Gas Valve Manifold
DO NOT USE THE GRILL if you cannot stop
a leak. Be sure the LP cylinder valve is closed.
If the LP cylinder is still leaking, contact your
LP dealer or local fire department.
Do not use any match or open flame, or smoke,
during leak testing.
Do not light a burner during leak testing.
The replacement hose assembly must be the one
identified in the Parts List of this manual.
GRILL PLACEMENT
For Your Safety
Minimum clearance required from sides and
back of unit to adjacent combustible
construction is 36 inches (91 cm).
Do not locate or use this outdoor cooking gas
appliance under overhead combustible
surfaces.
Maintain at least 10 feet (305cm) of clearance
from objects that can catch fire or sources of
ignition such as pilot lights, electrical
appliances, etc.
36 "
Keep any electrical supply cord and the fuel supply
hose away from any heated surfaces and water.
APARTMENT RESIDENTS
Check with your apartment manager regarding your
regulations for barbecues. If allowed, use only
outside on the ground floor. Do not use on balconies.