Technical Data; Safety Instructions - Milwaukee M12 TCBH Manual Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 12

TECHNICAL DATA

BATTERY CHARGER
Voltage battery pack ...............................................................
Input........................................................................................
DC Output...............................................................................
Output to M12 battery .............................................................
USB output .............................................................................
.............................................................................................
Battery charging time with M12 B2 .........................................
Battery charging time with M12 B3 .........................................
Battery charging time with M12 B4 .........................................
Battery charging time with M12 B6 .........................................
Weight according EPTA-Procedure 01/2003 ..........................
Recommended ambient charging temperature ......................
WARNING! Read all safety warnings and all
instructions. Failure to follow the warnings and instructions
may result in electric shock, fi re and/or serious injury.
Save all warnings and instructions for future reference.

SAFETY INSTRUCTIONS

Do not dispose of used battery packs in the household
refuse or by burning them. Milwaukee Distributors off er to
retrieve old batteries to protect our environment.
Only the following battery packs can be charged with this
charger:
Battery Cat.
DC Volts
Capacity
Cell No.
No.
M12B2
12
≤ 3.0 Ah
M12B3
12
≤ 3.0 Ah
M12B4
12
≤ 4.0 Ah
M12B6
12
≤ 6.0 Ah
Do not try to charge non-rechargeable batteries with this
charger.
Do not store the battery pack together with metal objects
(short circuit risk).
No metal parts must be allowed to enter the battery section
of the charger (short circuit risk).
Never break open battery packs or chargers and store only
in dry rooms. Keep dry at all times.
The battery clamps of the charger are fed by the mains
supply. Do not touch the tool with conducting objects.
Never charge a damaged battery pack. Replace by a new
one.
Before use check machine, cable, and plug for any
damages or material fatigue. Repairs should only be carried
out by authorised Service Agents.
This appliance is not intended to
be used or cleaned by persons
with reduced physical, sensory or
mental capabilities, or lack of
experience or knowledge, unless
they have been given instructions
concerning the safe use of the
appliance by a person legally
responsible for their safety. They
should be supervised whilst using
the appliance. Children shall not
use, clean or play with this
14
ENGLISH
M12 TCBH
.......................12 V
........... 5V
, 2,1 A
.......................12 V, 1,5 A
.......................12 V, 0,7 A
........... 9V
, 1,6 A
........... 5V
, 2,1 A
..................0-174 min
..................0-264 min
..................0-347 min
..................0-525 min
..................157,4 g
..................+5...+40 °C
appliance, which when not in use
should be secured out of their
reach.
Warning! To reduce the risk of fi re, personal injury, and
product damage due to a short circuit, never immerse your
tool, battery pack or charger in fl uid or al-low a fl uid to fl ow
inside them. Corrosive or conductive fl uids, such as
seawater, certain industrial chemicals, and bleach or bleach
containing products, etc., Can cause a short circuit.
SPECIFIED CONDITIONS OF USE
This charger charges 12V Milwaukee Li-Ion battery packs.
The charger can be used for supplying 12 V DC appliances
2 x 3
(e.g. heated jacket), 5V DC or 9 V DC appliances
(USB-port).
3
2 x 3
Do not use this product in any other way as stated for
normal use.
2 x 3
LI-ION BATTERIES
The rechargeable batteries are partially charged. The LED
on the battery indicates the state of charge.
If it is not used for long periods, the rechargeable battery will
switch to the non-operative state.
When fully discharged the rechargeable battery switches off
automatically (depth discharge not possible).
Under extreme circumstances, the internal temperature of
the battery could become to high. If this happens, the
battery will shut down.
Place the battery on the charger to charge and reset it.
The state of charge can be read by pressing the button on
the rechargeable battery. The battery can be left in the
electric tool while the reading is taken but it must be
switched off at least one minute beforehand (otherwise the
display will be inaccurate). The number of LEDs illuminated
indicates the state of charge. A fl ashing LED indicates a
max. power reserve of 10%.
As a general principle, if the electric tool should fail to work
after inserting the rechargeable battery, then the battery
should be plugged into the charger. The displays on the
battery and charger will then provide information about the
condition of the battery.
In low temperatures work may continue at reduced output.
CHARACTERISTICS
After inserting the battery into the reception of the charger
the battery will automatically be charged (red control lamp is
illuminated continuously)
When a hot or cold battery pack is inserted into the charger
(fl ashing red lamp), charging will begin automatically once
the battery reaches the correct charging temperature
(0°C...65°C). The max. charging current is fl owing when the
temperature of the Li-Ion-battery is between
The battery's charging time is between
(at 2.0 Ah), depending on the state of discharge.
Once the battery is fully charged, the LED on the charger
changes from red to green.
Remove the battery pack from the tool for charging when
convenient for you and your job. Milwaukee batteries do not
develop a "memory" when charged after only a partial
discharge. It is not necessary to run down the battery pack
before placing it on the charger.
As a general practice, it is best to unplug battery chargers
and remove batteries when not in use. No battery pack
damage will occur, however, if the charger and battery pack
are left plugged in.
If both LEDs fl ash alternately then the rechargeable battery
is either not fully pushed in or there is a fault with the battery
or charger. Take the charger and battery out of use
immediately for safety reasons and have them inspected by
a Milwaukee customer service centre.
TRANSPORTING LITHIUM BATTERIES
Lithium-ion batteries are subject to the Dangerous Goods
Legislation requirements.
Transportation of those batteries has to be done in
accordance with local, national and international provisions
and regulations.
• The user can transport the batteries by road without
further requirements.
• Commercial transport of Lithium-Ion batteries by third
parties is subject to Dangerous Goods regulations.
Transport preparation and transport are exclusively to be
carried out by appropriately trained persons and the
process has to be accompanied by corresponding experts.
When transporting batteries:
• Ensure that battery contact terminals are protected and
insulated to prevent short circuit.
• Ensure that battery pack is secured against movement
within packaging.
• Do not transport batteries that are cracked or leak.
Check with forwarding company for further advice
MAINTENANCE
Use only Milwaukee accessories and Milwaukee spare
parts. Should components need to be replaced which have
not been described, please contact one of our Milwaukee
service agents (see our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered.
Please state the Article No. as well as the machine type
printed on the label and order the drawing at your local
service agents or directly at: Techtronic Industries GmbH,
Max-Eyth-Straße 10, 71364 Winnenden, Germany.
0°C and 65°C.
1 min and 174 min
SYMBOLS
Please read the instructions carefully before
starting the machine.
Do not dispose electric tools, batteries/rechargeable
batteries together with household waste material.
Electric tools and batteries that have reached the end
of their life must be collected separately and returned
to an environmentally compatible recycling facility.
Check with your local authority or retailer for recycling
advice and collection point.
This tool is only suitable for indoor use. Never
expose tool to rain.
Class III equipment
Time-lag fuse 3.15 A
T3.15A
European Conformity Mark
National mark of conformity Ukraine
EurAsian Conformity Mark.
ENGLISH
15

Publicidad

Tabla de contenido
loading

Tabla de contenido