The fuse blows every time it is replaced
After charging for a whole day, the end of
charge indicator does not switch on.
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).
The warranty does not cover:
• Transit damage.
• Normal wear of parts (eg. : cables, clamps, etc..).
• Damages due to misuse (power supply error, dropping of equipment, disassembling).
• Environment related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc ...)
- A description of the fault reported.
WATTMATIC 100.140.170
Polarity reversal
Starting the vehicle
Wrong charge settings
Current overconsumption on the battery
The machine is charging a 6V battery in 12V
mode
The battery is damaged
Connect the + clamp to the battery's (+)
and the + clamp to the battery's (-).
Do not perform any starts when the charger
is connected.
Check that the selected voltage matches the
battery voltage.
Do not draw any of the battery's current
during the charge
Set the switch to 6V.
Change the battery.