Placing on waist belt and attaching the power cord
5. Thread the belt loop of the holster onto either the right or left side of the user's waist belt, depending on the orientation chosen.
6. Attach the Breathe Easy™ Power Cord or GVP 610 power cord to the adapter (Fig. 13). For the GVP, plug socket end of the power cord into the
prong receptacle on the front of the GVP-100 motor/blower. To power the motor/blower on, hold the power button on the adapter down for 1/2
second. When powered on, the indicator light on the TR-659 should blink for approximately one second and then turn off.
7. Position the holster assembly close enough to the motor/blower as to not strain the power cord, at the same time ensuring that the holster
assembly is placed in a location that allows the wearer to visually see the indicator light located on the top of the adapter.
To power the motor/blower off, hold the power button on the adapter down for 3 seconds. When there is approximately 15 minutes of charge left on
the TR-630 battery pack, the LED indicator light on the adapter will begin blinking. Immediately exit the contaminated area when the visual alarm
(LED indicator light) on the adapter activates.

INSPECTION AND MAINTENANCE

Failure to follow these User Instructions may reduce respirator performance, overexpose you to contaminants, and may result in injury,
sickness, or death.
a. Do not use with parts or accessories other than those manufactured by 3M as described in these User Instructions or on the NIOSH approval
label for this respiratory component.
b. The 3M™ Battery Adapter TR-659 is one component of an approved respiratory protection system. Always read and follow all User Instructions
supplied with your 3M headgear and other system components in order to ensure correct system operation.
c. Leave the contaminated area immediately if:
- Any part of the system becomes damaged.
- Airflow into the headtop decreases or stops.
- Breathing becomes difficult.
- Dizziness or other distress occurs.
- You smell or taste contaminants or irritation occurs.
Before each entry into a contaminated area, the following inspection must be performed to help ensure proper function of the respirator system.
Respirator systems are intended to help reduce exposures to certain contaminants and should always be handled with care and fully inspected prior
to use.
Inspection
3M™ Battery Adapter TR-659
Examine the outside of the TR-659 battery adapter for cracks, holes or signs of deterioration of the adapter housing. Examine battery connection pins
and power cord receptacle for signs of wear or corrosion. Replace adapter if damaged.
3M™ Leather TR-656 and Easy Clean Holsters TR-657
Examine the outside of the TR-657 easy clean holster and/or TR-656 heavy duty holster for holes, ripped seams or any other signs of wear.
Replace if damaged.
Follow the inspection procedure in the User Instructions for the Powered Air Purifying Respirator for which you are using; 3M™ Breathe Easy™
Powered Air Purifying Respirator (PAPR) or the GVP Powered Air Purifying Respirator (PAPR) and the User Instructions for the intended headgear. Keep
these User Instructions for reference.
Fig. 13
W WARNING
7
(English)