EMERGENCIES: If a gas leak cannot be stopped, or a fire occurs due to gas leakage, call the fire department.
EMERGENCIES: If a gas leak cannot be stopped, or a fire occurs due to gas leakage, call the fire department.
Emergencies
Possible Cause
Gas leaking from
•Damaged hose.
cracked/cut/burned
hose.
Gas leaking from LP
•Mechanical failure due to rusting or
cylinder.
mishandling.
Gas leaking from LP
• Failure of cylinder valve from
cylinder valve.
mishandling or mechanical failure.
Gas leaking between
•Improper installation, connection not
LP cylinder and
tight, failure of rubber seal.
regulator connection.
Fire coming through
• Fire in burner tube section of burner due
control panel.
to blockage.
Grease fire or
• Too much grease buildup in burner area.
continuous excessive
flames above cooking
surface.

Troubleshooting

Problem
Possible Cause
GAS ISSUES:
Burner(s) will not light
• Trying to light wrong burner.
using ignitor.
(See Electronic Ignition
• Burner not engaged with control valve.
Troubleshooting also)
• Obstruction in burner.
Continued on next
• No gas flow.
page.
ELECTRICAL ISSUES:
•Electrode cracked or broken; "sparks at
• Electrode tip not in proper position.
•Wire and/or electrode covered with
cooking residue.
•Wires are loose or disconnected.
•Wires are shorting (sparking) between
ignitor and electrode.
•Dead battery.
Burner(s) will not light
•Faulty electronic ignition circuit.
using ignitor.
•Sparking somewhere other than
Burner(s) will not
•See "GAS ISSUES:" on previous page.
match light.
•Improper method of match-lighting.
crack."
(Does not apply to SUREFIRE.)
between burner and electrode.
Prevention/Solution
•Turn off gas at LP cylinder or at source on natural gas systems. Discontinue use of
product and replace valve/hose/regulator. Once valve/hose/regulator replaced
conduct complete leak check per manual.
•Replace LP cylinder.
•Turn off LP cylinder valve. Return LP cylinder to gas supplier.
•Turn off LP cylinder valve. Remove regulator from cylinder and
visually inspect rubber seal for damage. See LP Cylinder Leak Test
and Connecting Regulator to the LP Cylinder.
•Turn off control knobs and LP cylinder valve. Leave lid open to
allow flames to die down. After fire is out and grill is cold, remove
burner and inspect for spider nests or rust. See Natural Hazard
and Cleaning the Burner Assembly pages.
• Turn off control knobs and LP cylinder valve. Leave lid open to
allow flames to die down. After cooling, clean food particles and
excess grease from inside firebox area, grease tray, and other
surfaces.
Prevention/Solution
• See instructions on control panel and in Use and Care section.
• Make sure valves are positioned inside of burner tubes.
• Ensure burner tubes are not obstructed with spider webs or other
matter. See cleaning section of Use and Care.
• Make sure LP cylinder is not empty.
• Replace electrode(s).
Main Burners:
• Tip of electrode should be pointing toward gas port opening on
burner. The distance should be 1/8" to 1/4". Adjust if necessary.
Sideburner:
• Tip of electrode should be pointing toward gas port opening on
burner. the distance should be 1/8" to 3/16". Adjust if necessary.
•Clean wire and/or electrode with rubbing alcohol and clean swab.
•Reconnect wires or replace electrode/wire assembly.
•Replace ignitor wire/electrode assembly.
•Replace with a new alkaline battery.
•See Troubleshooting Integrated Electronic Ignition section.
•Inspect wire insulation and proper connections. Replace wires if
insulation is broken.
•See "Match-Lighting" section of Use and Care.