Clean the cutters and guards.
C
Remove the retaining plate. Do not clean
more than one cutter and guard at a time,
2
since they are all matching sets. If you
1
accidentally mix up the cutters and guards, it
may take several weeks before optimal shaving
performance is restored.
Remove the hairs with the brush supplied.
Put the retaining plate back onto the shaving
unit.
Cause 3: shaving heads are damaged or worn.
B
Remove the retaining frame.
Remove the old shaving heads from the
shaving unit and replace them with new ones
Damaged or worn shaving heads (cutters and
guards) must only be replaced with the original
Philishave HQ8 Sensotec shaving heads.
Put the retaining frame back onto the shaving
unit.
2
Cause: the batteries are empty.
B
Recharge the batteries.
The shaver does not work when the