Steelcase CISCO DX80 Manual De Instrucciones página 11

Tabla de contenido

Publicidad

®
10.
Lift out puck well and rotate to original
orientation (10a). Reinstall IEC power block connection
to puck well power block (10b).
TIP:
Double check to be sure incoming power cord
is fully connected to the power block.
11.
Reinstall two (2) 2.5mm hex machine screws
that were removed on page 8.
NOTE:
To avoid damaging puck well, do not tighten
to the point of causing distortion of the plastic,
TIP:
Care should be taken when routing low
voltage power indication cord during reinstallation
of the kiosk puck / power housing. Double check
the puck cord length for sufficient length to reach
perimeter of worksurface.
12.
Reinstall the flocking plate that was
removed on Step 3. Press down until flat.
TIP: If excessive force is needed to seat the flocking
plate, stop and inspect for unintended interference.
13.
Loosely coil pucks and place puck in
housing. Close housing door to prevent damage
to pucks / housing during monitor installation.
14.
Double check all IEC and low voltage
connections. Reinstall the lower cover with
the four (4) flat head screws removed in Step 5.
10b
2.5MM HEX
MACHINE SCREW
11
Page 11 of 16
23466201 Rev E

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mt02dkMt02sk

Tabla de contenido