Maintenance

7

Maintenance intervals

7
Maintenance
Maintenance intervals
The brake resistor is maintenance−free. Nevertheless, a visual inspection must be executed
in short and regular intervals considering the ambient conditions.
Ensure that:
ƒ the environment of the brake resistor still corresponds to the operating conditions
included in the technical data.
ƒ no dust or dirt impedes the heat dissipation of the brake resistor.
ƒ the mechanical and electrical connections are correct.

Maintenance operations

Cleaning the brake resistor
1. Disconnect the standard device from the mains and wait at least three minutes.
2. Check temperature of the brake resistor and allow it to cool, if required.
3. Check the brake resistor for safe isolation from supply.
4. Clean brake resistor without using cleaning agents.
l
53
EDKRBS047R DE/EN/FR/ES/IT 8.0