Thermal Overload Protector; Extension Cord Use - Campbell Hausfeld CT1001 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operating Instructions
Maintenance (Continued)

THERMAL OVERLOAD PROTECTOR

This compressor is equipped with a
manual reset thermal overload protector
which will shut off motor if it becomes overheated.
If thermal overload protector shuts motor OFF frequently look
for the following causes:
1� Low voltage
2� Clogged intake port (located on pump crankcase)
3� Lack of proper ventilation
If the thermal overload protector is
actuated, the motor must be allowed to cool
down for 30 minutes before manually resetting.
After the unit has cooled down for 30 minutes, manually reset
the thermal overload protector by pushing the button shown in
Figure 5�
STORAGE
1� When not in use, store hose and compressor in a cool, dry
place�
2� Drain tank of moisture
3� Disconnect hose and hang open ends down to allow any
moisture to drain�

EXTENSION CORD USE

If an extension cord has to be used, use the appropriate cord based on the charts below� See Amp Rating decal on unit�
Length of Cord in Feet
AWG Size of Cord
Length of Cord in Feet
AWG Size of Cord
6
www.chpower.com
Figure 5
Extension cords for 120V / 3 to 4 Amp Units
25
50
18
18
Extension cords for 120V / 6 to 8 Amp Units
25
50
18
16
100
150
200
16
141
12
100
150
200
12
10
10
Thermal
overload
protector
250
300
400
12
10
10
250
300
400
8
6
6
500
8
500
6

Publicidad

Tabla de contenido
loading

Tabla de contenido