11.5 Changing the saw blade (fig. 1/2/14-17)
Remove the power plug!
Important!
Wear safety gloves when changing the saw blade.
Risk of injury!
• Swing the machine head (4) upwards and lock with the lock-
ing bolt (23).
• Loosen the retaining screw (5a) of the cover using a Phillips
screwdriver.
WARNING!
Do not fully remove this screw.
• Fold the saw blade guard (5) upwards until the saw blade
guard (5) is above the flange screw (28).
• With one hand insert the Allen key (C) in the flange screw
(28).
• Hold the Allen key (C) and slowly close the saw blade guard
(5) until it touches the Allen key (C).
• Firmly press the saw shaft lock (30) and slowly rotate the
flange screw (28) in clockwise direction. The saw shaft lock
(30) engages after no more than one rotation.
• Now, using a little more force, slacken the flange screw (28)
in the clockwise direction.
• Turn the flange screw (28) right out and remove the outer
flange (29).
• Take the blade (6) off the inner flange (31) and pull out
downwards.
• Carefully clean the flange screw (28), outer flange (29) and
inner flange (31).
• Fit and fasten the new saw blade (6) in reverse order.
• Fold the saw blade guard (5) downwards until the saw
blade guard (5) engages in the locking screw (5a).
• Re-tighten the locking screw (5a).
• Important!
The cutting angle of the teeth, in other words the direction of
rotation of the saw blade (6) must coincide with the direction
of the arrow on the housing.
• Before continuing your work make sure that all safety de-
vices are in good working condition.
• Important!
Every time that you change the saw blade (6), check to see
that it spins freely in the table insert (10) in both perpendicu-
lar and 45° angle settings.
• Important!
The work to change and align the saw blade (6) must be
carried out correctly.
11.6 Adjusting the laser (fig. 19-20)
If the laser (32) ceases to indicate the correct cutting line, you
can readjust the laser. To do so, open the screws (32b) and re-
move the front cover (32a). Loosen the Phillips head screws (E).
Set the laser by moving sideways until the laser beam strikes the
teeth of the saw blade (6).
After adjusting and tightening the laser, mount the front cover
by tightening both screws (32b) by hand.
The machine must be connected to the mains in order to adjust
the laser.
Attention!
Never press the ON/OFF switch (2) when adjusting
the laser. Danger of injury!
11.7 Service information
Please note that the following parts of this product are sub-
ject to normal or natural wear and that the following parts are
therefore also required for use as consumables.
Wear parts*: carbon brushes, saw blade, table insert (art.
no. 5901215010), saw dust bag
* Not necessarily included in the scope of delivery!
12. Transport
• Tighten the handle (11) to lock the rotary table.
• Press the machine head (4) downwards and secure with the
locking bolt (23).
• Fix the saw's drag function with the locking screw for drag
guide (20) in rear position.
• Carry the equipment by the fixed saw table (15).
• When reassembling the equipment proceed as described
under section 8 and 9.
13. Storage
Store the device and its accessories in a dark, dry and frost-
proof place that is inaccessible to children. The optimum stor-
age temperature is between 5 and 30˚C.
Store the electrical tool in its original packaging.
Cover the electrical tool in order to protect it from dust and
moisture.
Store the operating manual with the electrical tool.
14. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions. The cus-
tomer's mains connection as well as the extension
cable used must also comply with these regula-
tions.
• The product meets the requirements of EN 61000-3-11 and
is subject to special connection conditions. This means that
use of the product at any freely selectable connection point
is not allowed.
• Given unfavourable conditions in the power supply the prod-
uct can cause the voltage to fluctuate temporarily.
• The product is intended solely for use at connection points
where the following prerequisites apply:
a) A maximum permitted supply impedance "Z" (Zmax =
0.339 Ω) must not be exceeded.
b) A continuous current-carrying capacity of the mains of at
least 100 A per phase must be given.
• As the user, you are required to ensure that the connection
point at which you wish to operate the product meets one of
the two requirements, a) or b), mentioned above. As neces-
sary, consult your electric power company.
Important information
In the event of an overloading the motor will switch itself off. Af-
ter a cool-down period (time varies) the motor can be switched
back on again.
GB/IE
11