T60088 & T60288 Series Installation
5
Installation and Adjustment of the Temperature Knob
Failure to do so may cause injury.
1
2
Adjust temperature limit stop!
Turn on water supplies; let the water run at
both full hot and full cold to ensure the water
is running as hot/cold as possible. Place a
thermometer in a plastic tumbler, and hold
the tumbler in the water stream. Place the
temperature knob (1) onto the splines (2), then
rotate the temperature knob counter-clockwise
until you achieve your maximum desired
temperature from the outlet (not more than 120°
or the lower temperature mandated by your
local plumbing code).
If max temperature is not achieved before limit
stop (3) on temperature knob (1) meets the
91834
Rev. A
5
6
2
3
limit stop (4) on the volume control handle.
Remove the temperature control knob (1)
from splines (2). Rotate temperature control
knob (1) clockwise. Place temperature control
knob (1) back onto splines (2) and continue
to rotate counter-clockwise until maximum
desired temperature is achieved.Remove the
temperature knob (1) and replace onto the
splines (2), making sure that the temperature
knob limit stop (3) hits against the volume
handle limit stop (4) as shown. Secure the
temperature knob using screw (5) and place
button (6) in hole.
6