Troubleshooting

Try these remedies for common APS problems before calling for help. Call Tripp Lite Customer Service at
(773) 869-1234 before returning your APS for service.
SYMPTOM
APS does not provide
AC output (AC input present)
APS does not provide
AC output (AC input absent)
APS will not charge the
battery (AC input present)
All APS Indicator Lights are
OFF (AC input absent)
All APS Indicator Lights are
OFF (AC input is present or
absent)
All APS Battery Indicator
Lights are slowly flashing.
APS "LOAD" Battery Light
flashing
All APS Battery Lights are
rapidly flashing
APS red "BATTERY HI/MED/LO"
light is flashing
*User supplied
PROBLEMS
APS not properly connected to
utility power.
Circuit breaker is tripped.
APS shutdown due to excessive
battery voltage, indicating possible
charger failure. Line disconnected
to prevent permanent battery
damage.
APS is overheated.
APS is set to "OFF"
Operating Mode Switch is set
to "CHARGE ONLY".
Load or High Temperature fault.
Excessive battery discharge.
Connected batteries are dead.
(All Battery Indicator lights will be
flashing slowly.)
Battery fuse* is blown.
Battery cabling* is loose or degraded. Check and tighten or replace cabling.
APS charger failure.
This is normal if the APS is set
to "CHARGE-ONLY"
Excessive battery discharge.
Excessive battery discharge.
Inverter shutdown because load
is too high or temperature is too
high.
High battery voltage shutdown
during battery charging.
Inverter shutting down due to low
battery charge.
12
CORRECTIONS
Connect APS to utility power.
Reset circuit breaker.
Turn APS "OFF". Wait 1 minute and
switch to "AUTO/REMOTE".
Check air circulation near vents.
Set APS to "AUTO/REMOTE" or
"CHARGE-ONLY".
Set Operating Mode Switch to "AUTO/
REMOTE."
Turn APS "OFF". Wait 1 minute.
Remove overload. Check that vents
are clear for air circulation. Switch
to "AUTO/REMOTE".
Check battery condition.
Check and replace old batteries.
Check and replace fuse.
Turn APS "OFF". Wait 1 minute and
switch to "AUTO/REMOTE". If
automatic shutdown occurs, call
Tripp Lite Customer Service.
Use an auxiliary charger* to raise
battery voltage. Check external battery
connections and fuse. Automatically
resets when condition is cleared.
Use an auxiliary charger* to raise
battery voltage. Automatically resets
when condition is cleared.
Turn APS "OFF". Wait 1 minute.
Remove overload. Check that vents
are clear for air circulation. Switch
to "AUTO/REMOTE".
Check all charging sources. Reset by
cycling control switch to "OFF" then to
"AUTO/REMOTE" or "CHARGE-ONLY".
Prepare for loss of power to
connected equipment.