Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19
This may be very hazardous to health! The LARYVOX
also be destroyed or damaged.
EN
Cleaning Steps
Place LARYVOX
2-3 minutes for cleaning, or use a mild, neutral-pH washing lotion.
Then rinse with plenty of clear water and allow to dry in air.
Do not use any sharp-edged cleaning utensils!
Depending on the individual needs of the patient, which must be de-
termined by the treating physician, it may be necessary to immerse
the LARYVOX
212 degrees Fahrenheit) for at least 5 minutes but not more than
10 minutes.
Dry the product thoroughly with a clean and lint-free cloth after wet
cleaning.
2. Chemical Disinfection Instructions
Cold-disinfection of the LARYVOX
infectants is possible.
Disinfection should always be done if ordered by a doctor/physician
due to specific health concerns caused by disease, infection, or your
specific situation.
Disinfecting is generally indicated to prevent cross-infection and
in inpatient situations (e.g. hospitals, nursing homes, and/or other
health care facilities) to limit infections.
CAUTION
Always clean according to the cleaning procedure described
above before proceeding to disinfection (if applicable).
Disinfectants that release chlorine or that contain strong alkalis
or phenol derivatives must under no circumstances be used.
This could badly damage or even destroy the LARYVOX
Disinfection steps
For this purpose, OPTICIT
be used in accordance with the manufacturer's instructions.
As alternative, we recommend a disinfectant based on glutaric al-
dehyde as active ingredient. Always observe the area of application
and spectrum of activity specified for the disinfectant by the manu-
facturer.
After disinfection, the LARYVOX
roughly with sterile saline solution (NaCl 0.9%) and then dried.
Follow the instructions for the disinfectant.
Dry the product thoroughly with a clean and lint-free cloth after wet
cleaning.
X. STORAGE
Cleaned products that are not currently in use should be stored in
a dry environment in a clean plastic bag and protected from dust,
sunlight and/or heat.
XI. SERVICE LIFE
The LARYVOX
When used and looked after correctly, in particular observing the
instructions for use, cleaning, disinfection and maintenance provided
in the instructions for use, the LARYVOX
service life of up to 12 months.
The maximum period of use should not exceed 12 months.
XII. LEGAL NOTICES
The manufacturer Andreas Fahl Medizintechnik-Vertrieb GmbH will
not accept any liability for functional deficiencies, injuries, infections,
and/or other complications or other adverse events caused by unaut-
horised product alterations or improper use, care, and/or handling.
In particular, Andreas Fahl Medizintechnik-Vertrieb GmbH will not
accept any liability for damages caused by modifications to the
LARYVOX
were not carried out by the manufacturer himself. This applies both
to damages to the LARYVOX
consequential damages caused thereby.
When used beyond the period of use specified under Section V, and/
or use, treatment, maintenance (cleaning, disinfection) or storage
of the LARYVOX
laid down in these instructions for use, Andreas Fahl Medizintechnik-
Vetrieb GmbH will, as far as legally permissible, be free of any liabi-
lity, including liability for defects.
Sale and delivery of all Andreas Fahl Medizintechnik-Vertrieb GmbH
products is carried out exclusively in accordance with our General
Terms and Conditions of Business which can be obtained directly
from Andreas Fahl Medizintechnik-Vertrieb GmbH.
The manufacturer reserves the right to make changes to the product
at any time without notice. LARYVOX
Andreas Fahl Medizintechnik-Vertrieb GmbH, Cologne registered in
Germany and the EU member states.
PLUG to soak in clear, lukewarm water for approx.
®
PLUG in boiling water (100 degrees Celsius resp.
®
PLUG is a single-patient product.
®
PLUG or by repairs, if these modifications or repairs
®
PLUG in non-compliance with the specifications
®
PLUG with special chemical dis-
®
tube disinfectant (REF 31180) should
®
PLUG must be rinsed very tho-
®
PLUG has an expected
®
PLUG caused thereby and to any
®
is a trademark and brand of
®
10
PLUG may
®
PLUG.
®

Publicidad

Tabla de contenido
loading

Tabla de contenido