7.3 Feeding solenoid valve.

The drain solenoid valve is fitted with an input filter that must be
checked and cleaned periodically.
To reach the filter, the pipe connection A of the supply pipe must be
unscrewed: the filter is found inside the threaded bushing B of the
solenoid valve.
If cleaning becomes too frequent, it is advisable to install a cartridge
filter on the machine water supply line (see:
connections
).

7.4 Performing the washing/reset cycle

Check that the cycle is done periodically.
To check, carry out the following procedure:
Detach the end of the drainpipe not attached to the machine and insert it into a container to collect the water drained off.
Stop the humidifier by turning off the control humidistat: this starts the washing cycle.
If the cycle does not go on regularly, the water basin must be cleaned and the siphon.
ATTENTION: The NEB6500 is an air humidifier, so any other use to which it might be put, and which is not what it
was designed for (for example spraying insecticides, disinfectants, essences or any product other than water)
may be dangerous or compromise the good operation of the machine.
3.7 Hydraulic
- 19 -
Fig. 24