Intended Use - SMA SUNNY BOY STORAGE 2.5 Instrucciones Breves

Ocultar thumbs Ver también para SUNNY BOY STORAGE 2.5:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

1 Intended Use
1 Intended Use
The Sunny Boy Storage is a single-phase, AC coupled battery inverter for parallel grid operation.
The Sunny Boy Storage converts the direct current supplied by a battery into grid-compliant
alternating current. With a lithium-ion battery and the energy meter, the Sunny Boy Storage
becomes a system for increased self-consumption.
The Sunny Boy Storage must only be operated in connection with an intrinsically safe lithium-ion
battery approved by SMA Solar Technology AG. An updated list of batteries approved by SMA
Solar Technology AG is available at www.SMA-Solar.com.
The lithium-ion battery must comply with the locally applicable standards and directives and must
be intrinsically safe (see technical information "SMA Flexible Storage System - Detailed
explanations of the safety concept" for detailed explanations regarding the safety concept of
battery inverters by SMA Solar Technology AG). The battery management of the used lithium-ion
battery must be compatible with the Sunny Boy Storage. The entire battery voltage range must be
completely within the permissible input voltage range of the Sunny Boy Storage. The maximum
permissible DC input voltage of the Sunny Boy Storage must not be exceeded.
The Sunny Boy Storage is suitable for indoor and outdoor use.
The Sunny Boy Storage is not suitable for supplying life-sustaining medical devices. A power outage
must not lead to personal injury.
All components must remain within their permitted operating ranges and their installation
requirements at all times.
The product must only be used in countries for which it is approved or released by SMA Solar
Technology AG and the grid operator.
Use this product only in accordance with the information provided in the enclosed documentation
and with the locally applicable standards and directives. Any other application may cause
personal injury or property damage.
Alterations to the product, e.g. changes or modifications, are only permitted with the express written
permission of SMA Solar Technology AG. Unauthorized alterations will void guarantee and
warranty claims and in most cases terminate the operating license. SMA Solar Technology AG
shall not be held liable for any damage caused by such changes.
Any use of the product other than that described in the Intended Use section does not qualify as
appropriate.
The enclosed documentation is an integral part of this product. Keep the documentation in a
convenient place for future reference and observe all instructions contained therein.
The type label must remain permanently attached to the product.
2 Symbols
2
SBS25-1VL-10-IS-xx-14
Danger to life due to electric shock
The product operates at high voltages. All work on the product must be
carried out by electrically qualified persons only.
SMA Solar Technology AG
Quick Reference Guide

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sbs2.5-1vl-10

Tabla de contenido