G - STORAGE - SERVIcING
If you take care of your appliance properly, you will be able to enjoy using it for many years.
• Do not clean your appliance when it is being used. Wait until it has cooled down to avoid burns caused by hot parts
(griddle, grate, reservoir etc.).
• Once the unit is cold (approximately 15 minutes) remove the cooking plate and grate. Empty the water. Unscrew legs
from base.
• Clean greasy parts with soap and water or a non-abrasive detergent product.
• To simplify cleaning, the lid (wok), the cooking plates, grate, can be washed in a dishwasher. The legs can be cleaned
with a sponge (no washing powder).
• When cleaning, be careful to avoid clogging the burner holes. If the holes are clogged, for example by food that has
spilled over, open them with a non-metal brush.
• After cleaning, assemble the pieces of the unit, put the lid back on and lock by reversing steps A, B, C in Fig. 1.
• The legs should be stored as shown in Figure 18. Make sure to rotate the grid (6) to a position so that the u-shape spacer
doesn't rest on the grate feet (Fig. 14-iii), otherwise the lid couldn't be closed.
• The unit should be stored in a safe, secure, and dry place, out of the reach of children and never in a cellar.
• If the device has not been used for 30 days, check to see that cobwebs are not clogging the burner hose openings; this
could lead to decreased burner efficiency or to a dangerous ignition of gas outside the burner.
• If the appliance will not be used for a long period of time, disconnect the cylinder as indicated in section § F.
• Regularly check the condition of the hose and change it if it shows signs of ageing or cracking (see section § C-2).
• In the case of the injector becoming clogged (the cylinder still contains gas but the appliance will not light), do not try to
unclog it yourself. Return the appliance to your retailer.
H - POSSIBLE PROBLEMS / cORREcTIVE AcTION
Possible problems
The burner does not light up
The burner does not burn smoothly or goes
out
Unstable blowing flames
Large plume of flame on the burner surface
Flame at the injector
Burning leak around a union
Insufficient heat
Burning leak behind the adjustment knob
I - WARANTY PERIOD
Years
2
Probable causes / corrective action
• Poor gas supply
• regulator not operating properly
• Pipe, valve, venturi tube or burner holes obstructed
• Clean the venturi
• Check that gas is present
• Check the pipe connection
• Contact your servicing agent."
• New cylinder may contain air. Allow the appliance to operate and
the fault will clear itself
• Residual water, following the washing of the burner caps
• Contact your servicing agent.
• The venturi is obstructed (possibly cobwebs)
• Contact your servicing agent."
• The cylinder is almost empty
• Change the cylinder and the fault will clear itself
• Contact your servicing agent.
• Shut off the gas supply immediately
• Leaking union: tighten nuts or change pipe
• Contact your servicing agent.
• Injector or venturi tube obstructed
• Contact your servicing agent.
• Clean the venturi
• Defective valve
• Shut down the stove
• Contact your servicing agent.
21