3. Ceiling Fan Assembly
3.16
Route the three 80" motor leads through the hanger ball.
Reinstall the hanger ball (Figure 16) on the downrod as
follows:
Position the hanger ball pin through the two holes in the
downrod and align the ball so the pin is captured in the
groove in the top of the hanger ball.
Pull the hanger ball up tight against the pin and securely
NOTE: A loose setscrew could create fan wobble.
tighten the setscrew in the hanger ball.
WARNING
!
It is critical that the pin in the hanger ball is properly
installed and the setscrew securely tightened. Failure to
verify that the pin and setscrew are properly installed
could result in the fan falling.
3.17
The fan comes with black, blue and white leads that are
80-inches long.
Before installing the fan, measure up approximately
6 to 9-inches above top of hanger ball/downrod assembly
(Figure 17).
Cut off excess leads and strip back insulation 1/2-inch
from end of leads.
(continued)
PIN
Figure 16
Figure 17
Please contact 1-800-654-3545 for further assistance
11
4.5" DOWNROD
HANGER BALL
SETSCREW
6 to 9
INCHES
HANGER BALL/
DOWNROD
ASSEMBLY
emersonfans.com
U.L. Model No.: CF784-1