Troubleshooting Table - Kohler 1181168-5-B Instrucciones Importantes

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting (cont.)

Troubleshooting Table

Symptom
3.
The user interface does
not light up and does not
work.
4.
The user interface lights
up but does not work.
5.
The Auxiliary music does
not work.
Kohler Co.
Probable Cause
A. Power to the control amplifier is
not on.
B. The control amplifier must be
reset.
C. The control amplifier does not
work.
D. The user interface cable
connections are loose or
damaged.
E. The user interface does not
work.
A. The control amplifier must be
reset.
B. The control amplifier does not
work.
C. The user interface cable
connections are loose or
damaged.
D. The user interface does not
work.
A. Power to the control amplifier is
not on.
B. The control amplifier must be
reset.
C. The control amplifier does not
work.
D. The auxiliary music source
option is not selected on the
user interface.
E. The vibracoustic sound is
muted on the user interface.
The vibracoustic intensity is
F.
turned down on the user
interface.
G. The auxiliary-in or user
interface cable connections are
loose or damaged.
13
Recommended Action
A. Reset the circuit breaker to the
control amplifier, then check the
electrical power supply and
connections.
B. If the red LED on the control
amplifier is not blinking, unplug the
control amplifier for 30 seconds,
then plug in and restart.
C. If the red LED on the control
amplifier is still not blinking
following restart, replace the control
amplifier.
D. Inspect the cable for loose
connections or damage. Secure the
connections or replace the cable as
needed.
E. Replace the user interface.
A. If the red LED on the control
amplifier is not blinking, unplug the
control amplifier for 30 seconds,
then plug in and restart.
B. If the red LED on the control
amplifier is still not blinking
following restart, replace the control
amplifier.
C. Inspect the cable for loose
connections or damage. Secure the
connections or replace the cable as
needed.
D. Replace the user interface.
A. Reset the circuit breaker to the
control amplifier, then check the
electrical power supply and
connections.
B. If the red LED on the control
amplifier is not blinking, unplug the
control amplifier for 30 seconds,
then plug in and restart.
C. If the red LED on the control
amplifier is still not blinking
following restart, replace the control
amplifier.
D. Select the auxiliary music option on
the user interface.
E. Touch the [Mute] icon on the user
interface to turn off the mute
setting.
Turn up the vibracoustic intensity
F.
on the user interface.
G. Inspect the cables for loose
connections or damage. Tighten the
connections or replace the cables as
needed.
1181168-5-B

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido