4
Supply line Connection
Warning
Air hoses which are installed with a hose grommet must be additonally secured with
a hose clamp.
Design: Gravity-feed cup
1.
Fasten the compressed air hose to the air con-
nection (N
10) of the spray gun.
o
2.
Fill the gravity-feed cup with the material to be
sprayed. Close the cup.
3.
Switch on the pneumatic system.
The spray gun can be taken into operation.
Design: Material connection
1.
Fasten the compressed air hose to the air con-
nection (N
10) of the spray gun.
o
2.
Fasten the material supply hose to the material
connection (N
3.
To allow the air in the material hose to escape,
operate the trigger, until a uniform material
spray exits the nozzle; the gun can now be
closed again.
The gun is now ready to be operated.
5
Operational Handling
The following requirements must have been met before you can operate the spray
gun:
•
The spray air pressure must be applied at the spray gun.
•
The material pressure must be applied at the spray gun.
Note
The material pressure shall not exceed • 5 bar, as, otherwise, the functional relia-
bility of the spray gun will suffer.
9) of the spray gun.
o
Air connection
27
Material
connection
Air connection