AD Corinte W - ADCS
FR
RU
...25
FI
IT
...43
DE
...28
...31
DK
...46
...49

Publicidad

loading

Resumen de contenidos para Frico AD Corinte W - ADCS

  • Página 1 AD Corinte W - ADCS ...16 ...19 ...22 ...25 ...28 ...31 ...34 ...37 ...40 ...43 ...46 ...49...
  • Página 2 AD Corinte W - ADCS...
  • Página 3 AD Corinte W - ADCS...
  • Página 4 AD Corinte W - ADCS Fig 4...
  • Página 5 AD Corinte W - ADCS Fig 5...
  • Página 6 AD Corinte W - ADCS 1700/2200 1670/2170 Left connection Wall Right connection Cu ø22 Cu ø22 Fig 6a Min 180 mm Min 180 mm Fig 6b...
  • Página 7 AD Corinte W - ADCS Fig 6c Fig 6d Fig 7...
  • Página 8 AD Corinte W - ADCS ADCEH Ø8 2 alternatives for securing at the top.* Ø12 (2x) Ø8 for securing at the air curtain.* SE / NO / FR / RU / DE / NL / ES / PL / FI / IT / DK ) 2 alt.
  • Página 9 AD Corinte W - ADCS ADCS - SIRe Fig 8 SIRe...
  • Página 10 AD Corinte W - ADCS SIRe SIReB SIReAC SIReAA SIReRTX 70x33x23 mm SIReUR 114x70x50 mm SIReWTA SIReB SIReUR SIReCJ4 SIReCJ6 SIReCC603 SIReWTA SIReCC605 SIReCC610 10 m SIReCC615 15 m SIReCC640 40 m SIReAC/SIReAA SIReCC403 SIReCJ4/SIReCJ6 SIReCC405 SIReCC410 10 m SIReCC415...
  • Página 11: Wiring Diagrams

    AD Corinte W - ADCS Wiring diagrams Internal wiring diagram ADCS W 230V~ Internal Motor sensor protection 230V Yellow 230V 200V Orange 200V 170V 170V 145V Brown 145V 120V Black 120V 100V Green 100V Blue Blue Black 230V~...
  • Página 12 AD Corinte W - ADCS Wiring diagrams SIRe B Basic SIReUB1 SD230 SIReRTX SIReB1/B2/B1EC 230V~ (optional) ROOM Pot. Unit ID ACTUATOR SUPPLY SIReCC6XX L=2m (max 50 m) L=1,5m SIReCC6XX (max 50 m) SD230 SIReB1/B2/B1EC 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY...
  • Página 13 AD Corinte W - ADCS ADCS WH Supply water temperature: 110 °C Water temperature: 110/80 °C Room temperature: +18 °C Room temperature: +18 °C Outlet air temperature: +35 °C* Type Airflow Output Return Water Pressure Output* Outlet Water Pressure position...
  • Página 14 AD Corinte W - ADCS ADCS WL Supply water temperature: 80 °C Water temperature: 80/60 °C Room temperature: +18 °C Room temperature: +18 °C Outlet air temperature: +35 °C* Type Airflow Output Return Water Pressure Output* Outlet Water Pressure position...
  • Página 15: Technical Specifications

    AD Corinte W - ADCS Technical specifications Water heat - ADCS WH, coil for high temperature water (≥80 °C) (IP20) ∆t* Type Output* Airflow* Water Sound Motor Voltage Amperage Length Weight volume level* motor motor [kW] [°C] [dB(A)] [mm] [kg] ADCS17WH*¹...
  • Página 16: Funcionamiento

    7). A ciones de instalación y uso de Frico. continuación, ponga la cortina de aire sobre el perfil. Aplicación 6.
  • Página 17 AD Corinte W - ADCS Montaje en horizontal suspendida del En caso de montaje en vertical, la conexión techo del agua se puede efectuar por la parte 1. Instale soportes de suspensión o similar (no superior o por la inferior. La conexión por la...
  • Página 18: Mantenimiento

    AD Corinte W - ADCS Mantenimiento Seguridad Para garantizar el rendimiento y la fiabilidad • Asegúrese de que no haya nada cerca de la cortina de aire, es preciso revisarla al de las rejillas de aspiración y descarga menos dos veces al año, aunque la frecuencia que impida la circulación del aire por la...
  • Página 19 Main offi ce Frico AB Tel: +46 31 336 86 00 Box 102 SE-433 22 Partille mailbox@frico.se Sweden www.frico.se For latest updated information and information about your local contact: www.frico.se...