  • Página 1 Original instructions AR3500 ..16 ..25 ..30 ..35 ..21 ..40 ..45 ..50 ..55 ..60 ..65 ..70...
  • Página 2 AR3500 Introduktionssidorna består huvudsakligen av bilder. För översättning av de engelska texter som används, se respektive språksidor. The introduction pages consist mainly of pictures. For translation of the English texts used, see the respective language pages. Introduksjonssidene består hovedsakelig av bilder. For oversettelse av de engelske tekstene, se de respektive språksidene...
  • Página 3 AR3500 Type [mm] [mm] [mm] [mm] AR3510 1057 1016 1067 AR3515 1567 1526 1577 1466 AR3520 2073 2031 2083 1971 Mounting Fig. 1: The mounting brackets on delivery.
  • Página 4 AR3500 Mounting Fig. 2a: Mounting on threaded bars. Fig. 2b: Mounting on threaded bars inside unit.
  • Página 5: Water Connections

    AR3500 90° Service hatch Fig. 3: Function of the snap fixing Water connections Fig. 4: The water coil is connected inside the unit through holes which are made (during installation) on the upper side or through the side of the unit, possible places are marked with punch marks.
  • Página 6 AR3500 Accessories SIRe SIReB 673 09 57 SIReAC 673 09 64 SIReAA 673 09 66 SIReB SIReUR SIReRTX 673 09 22 70x33x23 mm SIReUR 673 09 21 114x70x50 mm SIReWTA SIReWTA SIReCJ4 SIReCJ6 SIReCC603 673 09 23 SIReCC605 673 09 24...
  • Página 7 AR3500 AR3500 A AR3500 W...
  • Página 8 AR3500 AR3500 E...
  • Página 9 AR3500 SIReB Basic AR3500 A SIReB1 SIReUB1 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY SIReB Basic - Parallel connection SIReB1 SIReB1 SIReUB1 230V~ 230V~ ROOM ROOM Pot. Pot. Unit ID Unit ID ACTUATOR SUPPLY ACTUATOR SUPPLY Wiring diagrams for SIReAC Competent, see manual for SIRe.
  • Página 10 AR3500 SIReB Basic AR3500 E SIReB1 SIReRTX SIReUB1 230V~ (optional) ROOM Pot. Unit ID ACTUATOR SUPPLY SIReB Basic - Parallel connection SIReB1 SIReB1 SIReRTX SIReUB1 (optional) 230V~ 230V~ ROOM ROOM Pot. Pot. Unit ID Unit ID ACTUATOR SUPPLY ACTUATOR SUPPLY...
  • Página 11 AR3500 SIReB Basic AR3500 W SIReB1 SD230 SIReRTX SIReUB1 (optional) ROOM 230V~ Pot. Unit ID ACTUATOR SUPPLY...
  • Página 12 AR3500 SIReB Basic - Parallel connection AR3500 W SIReB1 SD230 ROOM 230V~ Pot. Unit ID ACTUATOR SUPPLY SIReB1 SD230 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY SIReB1 SIReRTX SD230 SIReUB1 (optional) 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY Wiring diagrams for SIReAC Competent and SIReAA Advanced, see manuals for SIRe.
  • Página 13 AR3500 Output charts water AR3500 AR3500W Standard coil Supply water temperature:80 °C Water temperature: 80/60 °C Room temperature: +18 °C Room temperature: +18 °C Outlet air temperature: +35 °C* Type Airflow Output Return water Water Pressure Output * Outlet Water...
  • Página 14 AR3500 Output charts water AR3500 AR3500WLL Special coil Supply water temperature:55 °C Water temperature: 55/35 °C Room temperature: +18 °C Room temperature: +18 °C Outlet air temperature: +35 °C* Type Airflow Output Return water Water Pressure Output * Outlet Water...
  • Página 15: Technical Specifications

    12,6 1400/2800 17/13 40/58 230V~ 1567 18,3 2000/4000 18/14 41/60 230V~ 2073 AR3520W Technical specifications | AR3500 WLL water heated, coil for low temperature water (460 °C)   ∆t* Type Output* Airflow Sound Voltage Amperage Length Weight [kW] [m3/h] [°C]...
  • Página 16: Funcionamiento

    El espacio libre mínimo entre la salida y el Ámbito de aplicación suelo es de 1800mm. La cortina de aire AR3500 está disponible en 1. Los soportes de montaje (4 uds) van sujetos versión ambiente, de calor eléctrico o de calor a la unidad durante el transporte.
  • Página 17 3 y 5. Ver manual del SIRe. da servicio a la cortina . En Frico tenemos las adecuadas para las requeridas en la 1. La trampilla de mantenimiento se abre instalación.
  • Página 18: Mantenimiento

    AR3500 la suciedad y las obstrucciones, haciendo la izquierda, mirando la unidad desde el innecesario instalar un filtro independiente. interior de la sala. La versión de 2 metros tiene dos botones rojos, situados en la parte Revisión, mantenimiento y reparación central de la unidad.
  • Página 19 AR3500 4. Instale la batería nueva aplicando el mismo provisional a un enchufe sin dispositivo de procedimiento en orden inverso. protección, para que la humedad se evapore. La unidad puede tardar en secarse entre unas Vaciado de la batería de agua (W) horas y unos días.
  • Página 20 AR3500 Traducción de las páginas introductorias • Mounting = Montaje • water connections = Conexion del agua • See separate manual for xxx = Consulte el manual de xxx • Accessories = accesorios • Paralell connection = conexión en paralelo •...