Wiring Diagram; Maintenance Schedule - Campbell Hausfeld GN1200 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operating Instructions
Maintenance
STORAGE
If the generator is not to be used for
extended periods of time, the following
pre-storage procedures should be per-
formed:
1. Drain all fuel from the tank, lines,
and carburetor.
2. Drain oil while the engine is still
warm.
3. Remove spark plug. Clean off any
carbon deposits. Check for discol-
oration – plug should be tan in color.
Check the gap; it should be
0.7– 0.8mm.
4. Pour approximately one teaspoon of
oil into spark plug hole.
5. Pull starter cord several times to
spread the oil throughout the cylin-
der.
6. Slowly pull the starter cord until
resistance is felt. This indicates that
the piston is moving upward on the
compression cycle, and the intake
and exhaust valves are closed. (The
piston pushes a small amount of air
from the spark plug hole on com-
pression).
7. To clean air filter
– Remove filter
from generator.
Wash in a sol-
vent. Pour motor
oil (SAE #20) on filter, squeeze out
excess and reinstall in generator.
8. To clean fuel filter –
Stop engine. Turn fuel
switch to closed (hori-
zontal) position.
Remove fuel filter and disassemble.
Wash filter in a solvent. Dry with a
clean cloth. Reinstall in generator.
(Continued)

Wiring Diagram

Wiring Diagram Guide
1 . . . . . . . . . . . . . . . . . . . Rotor Rectifier
2 . . . . . . . . . . . . . . . . . . Rotor Assembly
3 . . . . . . . . . . . . . . . . . Starter Assembly
4 . . . . . . . . . . . . . . . . . . . . . . . . . AC coil
5 . . . . . . . . . . . . . . . . . . . . . Exciting coil
6 . . . . . . . . . . . . . . . . . . . . . . . . . DC coil
7 . . . . . . . . . . . . . . . . . . . . . . Connector
8 . . . . . . . . . . . . . . . . . . . . AC protector
9 . . . . . . . . . . . . . . . . . AC voltage meter
10 . . . . . . . . . . . . . . . . . . . . . . AC socket
11 . . . . . . . . . . . . . . . . . . . . . Condenser

Maintenance Schedule

Part
Spark plug
Oil
Valve Clearance
Fuel Line
Exhaust System
Carburetor
Cooling Fan
Starting System
Air Cleaner
Generator Bolts
Wiring diagram for GN1200
Item
Check condition, adjust gap
and clean. Replace if necessary.
Check oil level. Replace or fill if
necessary
Check and adjust
Check fuel hose for crack or
damage. Replace if necessary.
Check for leakage. Retighten
or replace gasket and bolts.
Check choke lever operation.
Check for damage.
Check starter operation.
Check and clean the element .
Check and tighten
(1) Valve clearance: Intake 0.13-0.20 mm, Exhaust 0.13-0.20 mm.
(2) Service more frequently when used in dusty areas.
4
12 . . . . . . . . . . . . . . . . . . . . DC protector
13 . . . . . . . . . . . . . DC rectifier DC socket
14 . . . . . . . . . . . . . . . . . . . . . Spark plug
15 . . . . . . . . . . . . . . . . . . . . . Ignition coil
16 . . . . . . . . . . . . . . . . . . . . . Oil level SW
17 . . . . . . . . . . . . . . . . . . . . . . Transition
18 . . . . . . . . . . . . . . . . . . . . . Engine SW
R . . . . . . . . . . . . . . . . . . . . . . . . . . . Red
B . . . . . . . . . . . . . . . . . . . . . . . . . . Black
Bl . . . . . . . . . . . . . . . . . . . . . . . . . . . Blue
Y . . . . . . . . . . . . . . . . . . . . . . . . . Yellow
G/Y . . . . . . . . . . . . . . . . . . Green/ Yellow
Before
First
Every 3
every
mo. or
mos. or
starting
20 hrs
50 hrs
(2)
Every 6
Every 12
mos. or
mos. or
100 hrs
300 hrs
(1)

Publicidad