GYS GYSPOT ARCPULL 200 Manual Del Usuario página 21

Ocultar thumbs Ver también para GYSPOT ARCPULL 200:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45
INSTALLATION – PRODUCT OPERATION
EQUIPMENT DESCRIPTION (FIG-1)
The GYSpot ArcPull 200 is a single-phase inverter welding machine with arc-pull technology making is suitable to weld
welding parts(threaded studs, insulation nails, pulling rings) on steel or aluminium based materials. It has a synergic
mode and a manual mode.
Power source GYSPOT ARCPULL 200
1- Keypad
2- On/Off switch
3- Positive dinse connector for gun cable
4- Negative dinse connector for gun cable
5- Base for gun control cable connector
Automatic gun GYSPOT ARCPULL 200
1- Trigger
2- Electrode holder locking nut
3- Studs locking scrollwheel
4- Gun control cable connector
5- Positive dinse
INTERFACE (HMI) (FIG-2)
1- Display
2- Button G+
3- Button G
4- Button D+
POWER SUPPLY AND POWER UP
This machine is fitted with a 16A socket type CEE7/7 which must be connected to a single-phase 230V (50 - 60 Hz)
power supply fitted with three wires and one earthed neutral. The GYSpot ArcPull is equipped with «Flexible voltage»
technology, needs to be installed on a electrical installation with earth, between 110V and 240V (50-60Hz) The absorbed
current (I1eff) is indicated on the device, for its maximum setting. Check that the power supply and its protection (fuse
and/or circuit breaker) are compatible with the current needed by the machine. This equipment is designed to operate
on an electrical installation equipped with a 16A curve C, D or K curve circuit breaker.
In some countries, it may be necessary to change the plug to allow the use at maximum settings. The user has to make
sure that the plug can be reached.
• The device is switched on by pressing the « I » on/off button
• The device turns into protection mode if the power supply tension is over 265V. If this is the case, the machine displays
POWER DEFAULT Normal functioning comes back once the power supply is under 265V.
WORKING OFF A GENERATOR
The machine can work with generators as long as the auxiliary power matches these requirements:
• The voltage must be AC, always set as specified, and the peak voltage below 400 V.
• The frequency must be between 50 and 60 Hz.
• The power must be at least 7kVA.
It is imperative to check these requirements as many generators generate high voltage peaks that can damage the
machine.
USE OF EXTENSION LEAD
This equipment can be connected to the electrical installation with an extension lead as long as it matches the following
requirements:
• Single-phase extension lead with earth conductor.
• The length must not exceed 10 m.
• The cable cross-section must not be less than 2.5 mm².
GYSPOT ARCPULL 200
6- Gas outlet for gun cable
7- Gas input connected to the bottle (15 l/min) (G1/4 D6)
8- Transport handle
9- USB port protection cap
10 - Power supply cable
6- Negative dinse
7- Gas connector
8- LED ON (green)
9- LED contact (blue)
10- LED fault (red)
5- Button D
6- Button Menu/Validate