Manual Settings - GYS GYSPOT ARCPULL 200 Manual Del Usuario

Ocultar thumbs Ver también para GYSPOT ARCPULL 200:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45
MAIN MENU
To access the Main Menu from the Synergic or Manual modes, press the button Menu/Validate
M enu Pr i nci pal
> Régl ages
M ode M anuel
Conf i gur at i on
Press the return button
SYNERGIC SETTINGS
Régl ages Syner gi e
> M at ér i au
> Fe
Gaz
ON
El ect r ode
anneau
EP. él ec.
1. 5 m m

MANUAL SETTINGS

Régl ages M anuel
Am or ce
> Q = 0
Pressing the Menu/Validate button
screen.
Press the return button
Range of settings for the
manual mode
Arcing
-10 to 10 (default value 0)
Penetration
10 to 60 A
and cleaning
0 to 200 ms
Arc
0 to 200 A
0 to 500 ms
Attachment
-10 to 10 (default value 0)
0 to 50 ms
Height
0.5 mm to 5 mm
GYSPOT ARCPULL 200
Press the keys G+ and G- to move the section cursor. Select the section by pressing the
button Menu/Validate
•« Settings » access the welding settings (synergic or manual).
• « Manual Mode » / « Synergic Mode» change the welding mode on the machine (synergic
mode <-> manual mode)
• « Configuration » gives access the advanced settings on the machine (language, gas
options, information, etc.)
to return to the welding screen.
Press the keys G+ and G- to move the left cursor (Material, Gas, Type and thickness of the
insert). Press the keys D+ and D- to modify the values of each item.
Pressing the Menu/Validate button
chine to the synergy welding screen.
Press the return button
Press the keys G+ and G- to browse the different values (arcing and attachment coeffi-
cients, duration, currents, height) of the drawn arc process (see chapter «Drawn arc wel-
ding process»).
Press the keys D+ and D- to modify the values (coefficients, duration, current, height).
confirms the manual settings and returns the machine to the manual welding
to ignore the settings and return to the Main Menu.
Comment
"The default value is set to ensure optimal arcing and stop the arc
from breaking up when pulling the insert while limiting the short-
circuit current.
Slightly increase the ignition in case of repeated arcing failures. "
Limited to 100A if product is connected to a 110Vac ±15% power
supply
The default value is set to ensure optimal attachment of the elec-
trode onto the metal support.
.
confirms the synergy settings and returns the ma-
to ignore the settings and return to the Main Menu.
EN
25