Tell the operator where the switch is so that it can be reached quickly in an
EMERGENCY.
To guarantee correct operation, the maximum voltage variation must be between +/
- 6% of the nominal value.
Check that the power line has appropriate section cables, is protected against
overcurrent and dispersions towards earth, in compliance with current standards.
In the event of an interruption to the electricity supply, check that all store electrical
appliances can reboot without causing the overload protections to intervene. If not,
alter the system in order to differentiate between the start-up of the various
devices.
The installer must supply the anchorage devices for all cables in and out of the unit.
Avoid having the casing come into contact with the electrical panel to avoid
electric shocks which could cause injury or death.
Check that the connectors of the illumination (shelves, ceiling, superstructure)
are inserted properly and blocked in their sockets so as to avoid
disconnection during cleaning and maintenance operations which could lead
to electrical shocks harmful to the operator.
The automatic thermomagnetic switch should be designed so as not to open the
neutral circuit without simultaneously opening the phases. In any case, the opening
distance for the contacts must be at least 3 mm.
Version with incorporated group:
The unit comes with a connection ready for a plug (NOT SUPPLIED). Attach a plug of
suitable capacity for the electrical connection, onto the power lead in compliance with
safety rules: yellow-green = earth sky blue = neutral brown =live
Do not connect any other appliances to the same socket (do not use multiple
sockets).
Ensure that the electrical cable is laid out so it cannot being damaged. Ensure it
does not constitute an accident risk.
13. Start-up, temperature control and adjustment
- specialised technician-
The refrigeration temperature is controlled through the mechanical thermometer
located on the suction plate (Rif. 16).
Temperature values are usually set in the factory during testing. If necessary, this can
be varied by using the graduated knob (E).
There is an electrical socket on the control panel (G) . This is designed to connect
external units (max 1000 W).
If the temperature is adjusted too low, it could affect the unit's regular function,
altering the normal thermostatic pauses.
Version with incorporated group:
Before plugging the unit in, or unplugging it, cut the power supply to the socket.
Insert the plug and turn on the power to the socket.
Turn the general switch (Rif. 17 Pos. A) of the control panel
The refrigeration system will start working immediately.
After approximately 60 minutes of operation with the unit empty, once the unit
temperature is stable, load the foodstuffs that have already been cooled to their
storage temperature.
Control panel
A - Light switch
B - Mains switch
C - Defrosting lamp
D - Defrosting timer
E - Thermostat
F - Thermometer
36