Victron energy BlueSolar MPPT100/15 Manual De Instrucciones página 7

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

3.3. Configuration of the controller (see figure 1 and 2)
There is a 4-pin connector available to select one of the three battery control options:
3.3.1. No bridge: BatteryLife algorithm (see 1.2.2.)
3.3.2. Bridge between pin 1 and pin 2: conventional (see 1.2.1.)
Low voltage load disconnect: 11,1V or 22,2V
Automatic load reconnect: 13,1V or 26,2V
3.3.3. Bridge between pin 2 and pin 3: conventional (see 1.2.1.)
Low voltage load disconnect: 11,8V or 23,6V
Automatic load reconnect: 14V or 28V
3.4 LEDs
Green LED: indicates which load output control algorithm has been chosen.
On: one of the two conventional load output control algorithms (see Fig 2)
Blinking: BatteryLife load output control algorithm (see Fig 2)
Yellow LED: signals charge sequence
Off: no power from PV array (or PV array connected with reverse polarity)
Blinking fast: bulk charge (battery in partially charged state)
Blinking slow: absorption charge (battery charged to 80% or more)
On: float charge (battery fully charged)
3.5 Cable connection sequence (see figure 3)
First: connect the cables to the load, but ensure that all loads are switched off.
Second: connect the battery (this will allow the controller to recognize system voltage).
Third: connect the solar array (when connected with reverse polarity, the controller will heat
up but will not charge the battery).
The system is now ready for use.
3.6 Connecting an inverter
The load output can be used to supply DC loads and simultaneously to control an inverter.
The Victron inverters model Phoenix 12/800, 24/800, 12/1200 and 24/1200 can be
controlled by connecting the left side connection of the inverter remote control directly to the
solar charger load output (see figure 4).
For the Victron inverters model Phoenix 12/180, 24/180, 12/350, 24/350, the Phoenix
Inverter C models and the MultiPlus C models an interface cable is needed (MPPT 70/15 to
inverter remote on-off cable, article number ASS030550100, see figure 5).
5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Bluesolar mppt 100/15

Tabla de contenido