EGAmaster EGATronik 51664 Manual De Instrucciones página 23

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Note:
• lf the measured capacitar is short-circuited or the capacitance exceeds the maximum range,
the LCD will display "OL".
• When measuring capacitance >400µF, it may take sorne time to steady the readings.
• Before measuri ng, fully discharge all capac itors (espec ially for capacitors with high
voltage) to avoid damage to the meter and user.
Temperature Measurement (Picture 5)
1) lnsert the positive pole of the temperature probe into the "V °C
negative pole into the "COM" jack.
2) Turn the function switch to the "ºC/°F" position and the LCD will display room temperature.
3) Fix the temperature probe on the object to be tested, and read the temperature value of the
tested object directly from the display after a few seconds.
4) Press the SELECT button to switch between ºC and ºF.
Note:
• The ambient temperature of the meter should be in the range of 18-28ºC , othe rwise it will
cause measurement error.
• The positive and negative peles of the temperature probe should be properly connected. Do
not measure non-insulated live objects to avoid incorrect readings.
• Do not input voltage higher than 30V to avoid personal injury.
Non-contact AC Electric Field Sensing (NCV, Picture 6)
The electric field sensing sensitivity is divided into two levels ("EFHI" and "EFLo"). The
meter defaults to "EFHI". Select different sensitivity levels for measurement according to the
intensity of the measured electric field. When the electric field is around 220V (AC) 50Hz/60Hz,
select "EFHI"; when the electric field is around 110V (AC) 50Hz/60Hz, select "EFLo".
Red
Black
Picture 5
Hz" jack and
23

Publicidad

Tabla de contenido
loading

Tabla de contenido