Temperature should be within 18ºC~28ºC and the fluctuation range should be within ±1ºC.
When the temperature is <18ºC or >28ºC, add temperature coefficient error 0.1x (specified
accuracy) /°C.
Capacitance
Range
4.000nF
40.00nF
400.0nF
4.000uF
40.00uF
400.0uF
4.000mF
• Measured value = displayed value - open circuit value of the test teads (For capacitance
≤100n F, it is reco mme nded to use "REL" measurement mode.)
• For capacitance range, open circuit allows least significant digit ≤20.
Temperature
Range
-40ºC~40ºC
40ºC~500ºC
500ºC~1000ºC
-40ºC~104ºC
104ºC~932ºC
932ºC~1832ºC
NCV
Range
NCV
Test results may be affected by different socket designs or wire insulation thickness.
Resolution
0.001nF
0.01nF
0.1nF
0.001uF
0.01uF
0.1uF
0.001mF
Resolution
1ºC
1ºF
Electric field sensing
sensitiity level
EFLo
EFHI
Accuracy
±(4.0%+10)
±(4.0%+5)
±10%
Accuracy
±4ºC
±(1.5%+5)
±(2.0%+5)
±6ºF
±(2.0%+6)
±(2.5%+4)
Overload Protection
To sense the wire above 24±6V and identify
whether the mains socket is charged.
To sense the wire above 74V±12V, to identify
whether the mains socket is charged, or
to judge the live/neutral wire of the socket
according to the intensity of the sensing.
Overload Protection
600Vrms
Overload Protection
600Vrms