2.7.1 TO FILL THE FUEL TANK

1. Remove the fuel tank cap.
Figure 8 - Fuel Tank Cap
FILL TANK UNTIL
FUEL IS TWO (2)
INCHES BELOW
THE TOP
2. Add fuel slowly, stopping about 2 inches below the top of the
filler neck.
3. Replace the fuel tank cap. Make sure the valve on the fuel cap
is in the "OFF" position.
4. If the generator is going to be started, refer to the section
"STARTING THE GENERATOR" for additional directions on
priming the fuel system.

2.8 ADDING ENGINE OIL

All oil should meet minimum American Petroleum Institute (API)
Service Class SJ, SL or better. Do not use any aftermarket
additives.
Select the oil's viscosity grade according to the expected operating
temperature, only a little more than one-half quart is needed.
Above 40° F, use SAE 30
Below 40° F to 10° F, use 10W-30
Below 10° F, use synthetic 5W-30
1 0 W- 30
1 0 W - 3 0
Sy nthetic 5W-30
Sy nth et i c 5 W - 3 0
8
Section 3 — Maintenance
Portable Generator System
FUEL
TANK
CAP
S A E 3 0
S A E 3 0

2.8.1 TO ADD ENGINE OIL TO THE CRANKCASE

1. Place the unit on a firm, level surface.
2. Remove the Left Side Service Cover.
3. Remove the oil fill cap, located on the bottom of the engine
crankcase.
4. Add the recommended engine oil slowly, stopping frequently
to check the level. The full level is the base of the threads in
the filler neck.
5. Replace the oil fill capand tighten.
6. Always check the oil level before starting the generator
engine.
Figure 9 - Oil Fill
FULL OIL LEVEL
IS THE BOTTOM
OF THESE
THREADS
OIL FILL CAP
DO NOT overfill the engine crankcase with oil.
High oil pressure may result, causing
premature engine wear and damage.

3.1 GENERATOR MAINTENANCE

Proper care will ensure maximum performance of your generator.
Generator maintenance consists of keeping the unit clean and dry.
Operate and store the unit in a clean dry environment where it will
not be exposed to excessive dust, dirt, moisture or any corrosive
vapors.
Cooling air slots in the generator must not become clogged with
snow, leaves, or any other foreign material.
Check the cleanliness of the generator frequently and clean when
dust, dirt, oil, moisture or other foreign substances are visible on
its exterior surface.