Technical data
General data and operating conditions
Environmental conditions
Climate
Storage
Transport
Operation
Site altitude
Pollution
Vibration resistance
Transport
Operation
Mounting conditions
Mounting place
Mounting position
Free space
Connecting cables
«
Controller
filter
«
Filter
motor
38
IEC/EN 60721−3−1
IEC/EN 60721−3−2
IEC/EN 60721−3−3
EN 61800−5−1
2
(9.81 m/s
= 1 g)
IEC/EN 60721−3−2
EN 61800−2
Germanischer
Lloyd
IEC/EN 60068−2−6
1K3 (−25 ... +60 °C)
2K3 (−25 ... +70 °C)
3K3 (−10 ... +55 °C)
Current derating at +40 ... +55 °C: 2.5 %/°C
0 ... 4000 m amsl
1000 ... 4000 m amsl: Current derating 5 %/1000 m
Degree of pollution 2
2M2
2 ... 9 Hz: Amplitude 3.5 mm
10 ... 200 Hz: Acceleration resistant up to 10 m/s
200 ... 500 Hz: Acceleration resistant up to 15 m/s
5 ... 13.2 Hz: Amplitude ±1 mm
13.2 ... 100 Hz: Acceleration resistant up to 0.7 g
10 ... 57 Hz: Amplitude 0.075 mm
57 ... 150 Hz: Acceleration resistant up to 10 m/s
In the control cabinet, as close as possible to the
controller
Dependent on the payload of the control cabinet wall
Lightweight filters: suspended, fixing bracket to the
sides
Heavy filters: vertical, fixing bracket below
100 mm to the side and above
As short as possible, shielded
Max. 200 m shielded or max. 300 m unshielded
l
2
2
EDKZS3X200 DE/EN/FR/ES/IT 4.0