GYS GYSFLASH 3.48 PL Manual De Usario página 10

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
Translation of the original manual
1
Step
: Analysis
Analysis of the battery condition (charge level,polarity rever-
sal, incorrect battery connected...)
2
Step
: Recovery (1 A)
Recovering damaged elements due to a prolonged deep
discharge.
3
Step
: Test
Sulfated battery test
4
Step
: Desulfation (62 V)
Battery desulfation algorithm.
• Lithium-ion charging curve :
The GYSflash 3.48 PL uses an advanced 8-step Lithium charging curve that guarantees the optimal performance of your lithium
battery.
1
Step
: Analysis
Analyses the state of the battery (charge level, polarity inversion,
incorrect battery connected...)
2
Step
: Recovery (1 A)
Recovery algorithm following a deep discharge.
3
Step
: Charging (3 A)
Maximum current fast charge to reach an 80% charge level.
4
Step
: Absorption
Constant voltage charging to bring the charge level to 98%.
/
LiFePO4
51.8 V
Li-ion
53.3 V
10
10
GYSFLASH 3.48 PL
/
55.2 V
57.4 V
5
Step
: Charge (3 A)
Maximum current fast charge to reach an 80% charge level.
6
Step
: Absorption (58.4 V)
Constant voltage charge to reach 100% charge level.
7
Step
: Floating charge (54.4 V)
Maintaining the battery charge level at its maximum.
5
Step
: Test
Charge retention test.
6
Step
: Supplement
Reduced current charge to reach 100% charge level.
7
Step
: Equalization / Balancing
Balancing the battery cells
/
LiFePO4
54 V
Li-ion
54.6 V
8
Step
: Floating charge
Maintain the battery charge level at its maximum with main-
tenance charge every 10 days.
/
LiFePO4
51.8 V
Li-ion
53.3 V
EN
/
57.6 V
58.8 V
/
55.2 V
57.4 V

Publicidad

Tabla de contenido
loading

Tabla de contenido