To reduce the risk of electric shock, insure electricity
1.
has been turned off at the circuit breaker or fuse box
before beginning.
All wiring must be in accordance with the National
2.
Electrical Code ANSI/NFPA 70-1999 and local electrical
codes. Electrical installation should be performed by a
qualified licensed electrician.
CAUTION: To reduce the risk of personal injury, use
3.
only the screws provided with the electrical box.
The outlet box and support structure must be securely
4.
mounted and capable of reliably supporting 35 lbs. (15.9
kg). Use only UL Listed outlet boxes marked "Accept-
able for Fan Support of 35 lbs. (15.9 kg) or less."
CAUTION: The fan must be mounted with a minimum
5.
of 7 feet clearance from the trailing edge of the blades
to the floor.
Do not operate reversing switch while fan blades are
6.
in motion. Fan must be turned off and blades stopped
before reversing blade direction.
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL
INJURY, MOUNT TO OUTLET BOX MARKED "ACCEPTABLE FOR
FAN SUPPORT OF 35 LBS. (15.9 KG) OR LESS", AND USE SCREWS
PROVIDED WITH THE OUTLET BOX.
TO REDUCE THE RISK OF PERSONAL INJURY, DO NOT BEND THE
BLADE BRACKETS (ALSO REFERRED TO AS ("FLANGES") DURING
ASSEMBLY OR AFTER INSTALLATION. DO NOT INSERT OBJECTS IN
THE PATH OF THE BLADES.

1. Safety Rules

READ AND SAVE THESE INSTRUCTIONS
Avoid placing objects in path of the blades.
7.
To avoid personal injury or damage to the fan and other
8.
items, be cautious when working around or
cleaning the fan.
Do not use water or detergents when cleaning the fan or fan
9.
blades. A dry dust cloth or lightly dampened cloth will be
suitable for most cleaning.
After making electrical connections, spliced conductors
10.
should be turned upward and pushed carefully up into
electrical box. The wires should be spread apart with the
grounded conductor and the equipment-grounding
conductor on one side of the electrical box and ungrounded
conductor on the other side of the electrical box.
Electrical diagrams are for reference only. Light kits that
11.
are not packed with the fan must be UL Listed and marked
suitable for use with the model fan you are installing.
Switches must be UL General Use Switches. Refer to the
instructions packaged with the light kits and switches for
proper assembly.
All set screws must be checked and retightened where
12.
necessary before installation.
Suitable for use with solid-state speed controls.
13.
TO REDUCE THE RISK OF SHOCK, THIS FAN MUST BE INSTALLED
WITH AN ISOLATION CONTROL/SWITCH.