Important; Tools Required - Bradley Vernatherm S59-4008 Guia De Inicio Rapido

Válvula mezcladora termostática para lavamanos/llaves
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Model S59-4008
Read this installation manual completely to ensure proper installation, then file it with the owner
or maintenance department. Installation and final temperature adjustment along with compliance
Installation
and conformity to local codes and ordinances is the responsibility of the installer.
Separate parts from packaging and make sure all parts are accounted for before discarding any
Packing List
packaging material. If any parts are missing, do not begin installation until you obtain the missing parts.
T H
IS
E
S ID
U P
Flush the water supply lines before beginning installation. To comply with ASSE 1017, this valve
must be installed with check valves on the hot and cold inlets.
Product warranties may be found under "Product Information" on our web site at www.
bradleycorp.com.
Supplies recommended
• Shut-off on the outlet if tempered water is supplied to a remote location
• Shut-off on the inlets/supplies

Tools required

• Adjustable wrench (for cap removal) and to loosen locking nut
• Needle-nose pliers (for piston removal)
• Blade screwdriver (for temperature adjustment)
Installation
1 . Install check valves into valve assembly as shown .
NOTE: Observe direction of arrow on check valve when assembling.
2 . Slide tailpiece nuts over Hot and Cold supplies and valve outlet supply .
3 . Thread or solder tailpieces to Hot and Cold supplies and to valve outlet .
NOTE: Do not solder tailpieces when attached to the valve assembly or the valve may be damaged.
4 . Insert fiber washer between tailpiece and valve assembly for Hot and Cold supplies . Tighten tailpiece nuts onto
valve body .
5 . Pressurize the thermostatic mixing valve and check for pipe leaks .
NOTE: This valve is NOT factory preset. Upon installation, the temperature of this valve must be checked and
adjusted to ensure delivery of a safe water temperature . Water in excess of 110°F (43°C) may cause scalding .
6 . Check the temperature when approximately 1 .0 GPM water flow is reached and adjust if necessary (the range
of the valve is 95°F – 115°F (35°C – 46°C) . To adjust the temperature, follow the procedure below:
• Loosen temperature locking nut with wrench .
• Using a blade screwdriver, turn the adjustment stem counterclockwise to increase the temperature or
clockwise to decrease the temperature .
• Once desired temperature has been reached, tighten lock nut to prevent change in temperature .
7 . Shut the hot water inlet off by closing either the hot water check valve or inlet valve . While the hot water supply
is turned off, check to make sure the cold water flow is reduced . If the cold water is reduced properly, reopen
the hot water supply .
8 . Shut the cold water inlet off by closing either the cold water check valve or inlet valve . While the cold water
supply is off, check to make sure that the hot water flow has shut down .
2

IMPORTANT!

3/24/2014
Bradley • 215-1297 Rev. H; ECN 14-09-017
Installation

Publicidad

Tabla de contenido
loading

Tabla de contenido