1
User
The Soft Stop type SPC11−...−ASI has been designed for
fitting into a machine or an automation system and is only
suitable for use in a bus system in accordance with the
AS−Interface specifications. In conjunction with permitted
drives and measuring systems, as well as with a propor
tional directional control valve type MPYE−5−..., the SPC11
permits fast movement into two end positions set with
fixed stops as well as into one or two intermediate posi
tions.
Please note
This brief summary is intended only for users who are
familiar with the SPC11. Please observe the safety in
structions as well as the information on the permitted
combinations of valves, drives and measuring systems.
These can be found in the System manual for the
SPC11−...−ASI (type P.BE−SPC11−ASI−SYS−...) and in the
relevant Drive−specific supplement."
Caution
Always switch on the operating voltage supply first and
then the compressed air supply.
Before carrying out installation and/or maintenance
work, switch off the following power supplies either
simultaneously or in the following sequence:
1. the compressed air supply
2. the operating voltage for the SPC11.
Festo SPC11−...−ASI 0511b English
instructionsEnglish
15