In-Line Blower - Best WPP9 Manual De Usario

Ocultar thumbs Ver también para WPP9:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALL THE DUCTWORK
(WPP9IQ and WPP9IQT)
NOTE: To reduce the risk of fire, use only
metal ductwork.
1. Decide where the ductwork will run
between the hood and the outside.
2. A straight, short duct run will allow the hood
to perform most efficiently.
It is recommended that there be a minimum
of 6" of straight duct from to an elbow for 8"
duct and 12" for 10" duct.
3. Long duct runs, elbows, and transitions will
reduce the performance of the hood. Use
as few of them as possible.
4. Install a roof or wall cap. Connect 8" WPPIQ
(or 10" WPPIQT) round metal ductwork to
cap and work back towards hood location.
Use duct tape to seal the joints between
ductwork sections (Fig.6).

IN-LINE BLOWER

DECORATIVE
FLUE
HOOD
24" TO 36" ABOVE
COOKING SURFACE
- 9 -
ROOF CAP
8" OR 10" ROUND
DUCT
8" OR 10" ROUND
8" DUCT (5 - 1/8")
10" DUCT (5 - 3/8")
CENTERLINE OF
DUCT TO WALL
FIG. 5
WALL
CAP
ELBOW
FIG.6

Publicidad

Tabla de contenido
loading

Tabla de contenido