ASSEMBLY INSTRUCTIONS
7. Thread chain (K) through screw collar ring (H) and
canopy (A). Using the open chain links on chain
(K), attach one end to screw collar loop (I) and the
other end to threaded loop (J). Weave the fixture
electrical and ground wires through every other
chain link and pass through threaded nipple (C) into
outlet box. Lower the screw collar ring (H) and
canopy (A) over the chain (K).
NOTE: Add or remove chain links once desired
length is established. Trim extra cabling leaving
six inches of extra wire protruding from the screw
collar loop and threaded nipple.
CAUTION: To avoid damage from falling, make
sure the open chain links are fully closed once
assembled.
8. Wire connection guide:
Ground wire:
• For installation in the United States: Wrap
ground wire from outlet box around ground
screw preassembled on mounting bracket
(B) no less than 2 in. from wire end. Tighten
ground screw. If fixture is supplied with a
ground wire, connect to outlet ground wire
with a wire connector (AA).
• For installation in Canada: If fixture is
supplied with ground wire, wrap ground wire
around ground screw on mounting bracket
(B). Tighten ground screw. Connect fixture
ground wire to outlet ground wire with the
wire connector (AA).
Supply wires:
• Connect the Neutral (White) supply wire from
the outlet box to the Neutral fixture wire
(Parallel Cord "D" shaped and ribbed).
• Connect the Hot (Black) supply wire from the
outlet box to the Hot fixture wire (Parallel
Cord round and smooth).
Hardware Used
Wire Connector
AA
7
Outlet
Box
8
BARE COPPER,
OR GREEN
GROUND
SUPPLY WIRE
BLACK SUPPLY
WIRE
WHITE SUPPLY
WIRE
x 3
6
I
C
K
A
H
J
BARE COPPER,
AA
OR GREEN
GROUND
FIXTURE
WIRE
PARALLEL
FIXTURE CORD
(ROUND AND
SMOOTH)
PARALLEL FIXTURE
CORD ("D" SHAPED
AND RIDGED)