DPA−...
Connect the compressed air
S
tubing as shown in Fig. 7.
With an output pressure greater than
10 bar, make sure that the limits for the
connecting elements at output 2 are
observed (if necessary fit the DPA−... in
the tubing).
Type
Connection number
Connection size
Tightening torque
Tubing type:
for low pressure
for high pressure
Fig. 7
5
Commissioning
Warning
The sudden escape of compressed air can
cause injury.
S Make sure that the compressed air out
puts of the DPA−... for exhaust 3 and
high pressure 2 are connected.
Please note
High compressed air forces can damage equipment further along the com
pressed air path.
S Make sure that equipment switched downstream of the DPA−... is designed
for the maximum high pressure which can be achieved.
Festo DPA−... 0309a English
Fig. 6
DPA−63−...
1
Compressed air input
2
High pressure output
3
Exhaust
y'
max. 25 Nm
PAN−12x1.75
PAN−10x1.5
Fig. 8
3
2
1
DPA−100−...
½'
max. 40 Nm
PAN−16x2
PAN−12x1.75
3
2
15