Hilti CP 620 Manual De Instrucciones página 7

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21
CAUTION
The product may present hazards when used incorrectly by untrained personnel or when not
used as directed.
Keep other persons, especially children, away from the working area.
6. Before use
1
1. Hold the cartridge with the screw cap facing upwards.
2. Open the screw cap. (-CAUTION- Do not point the cartridge towards persons.)
3. Screw on the mixing nozzle. Tighten it securely.
4. Press the locking lever on the DSC dispenser and hold it in this position.
5. Pull the dispenser piston rod back as far as it will go and release the locking lever.
6. Insert the cartridge with fitted mixing nozzle in the DSC dispenser.
7. Foam application
-NOTE-
Read the instructions before using the product. The material around the openings must be in sound con-
dition, dry and free from dust and grease
foam is easier to dispense at a higher temperature). Do not use at temperatures above 25°C.
7.1 Applying the foam
1. Press the trigger on the dispenser 5 times. The initial portion of foam then ejected is unevenly mixed
and should be caught in the plastic bag and disposed of.
2. Inject foam into the opening by pressing the trigger. -NOTE- Begin at the rear of the opening, working
towards the front and from the bottom upwards.
• If the trigger is pressed slowly, the foam escaping from the nozzle is already slightly expanded and
can thus be built up easily in the opening.
• If the trigger is pressed quickly, the consistency of the foam tends to be more liquid. The foam then
flows better into gaps around and between the cables.
• Do not push the mixing nozzle into the previously applied foam.
• The foam may become solid in the mixing nozzle if the trigger is pressed too slowly or after a long
pause during application of the foam (> 15 seconds)
before application of the foam can continue.
• Should the foam in the mixing nozzle become hard, do not attempt to continue dispensing the foam
by applying higher pressure. Fit a new mixing nozzle.
3. Mount the installation plate beside the opening.
Printed: 30.07.2015 | Doc-Nr: PUB / 5188045 / 000 / 03
CP 620 Expanding Fire Seal
. The cartridge must have a temperature of at least 15°C (the
2
3
4
. The mixing nozzle must then be replaced
3
5
en
en
de
de
fr
fr
it
it
nl
nl
es
es
pt
pt
el
el
no
no
cs
cs
sk
sk
bg
bg
ro
ro
ru
ru
tr
tr
th
th
7

Publicidad

Tabla de contenido
loading

Tabla de contenido