Descargar Imprimir esta página
Leviton Opt-X SPLCS-12A Instrucciones De Instalación
Leviton Opt-X SPLCS-12A Instrucciones De Instalación

Leviton Opt-X SPLCS-12A Instrucciones De Instalación

Ocultar thumbs Ver también para Opt-X SPLCS-12A:

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

SPLCS-12A
SPLCS-12L
SPLCS-12V
SPLCS-124
SPLCS-244
SPLCS-24A
SPLCS-24L
SPLCS-24V
SPSCS-12A
SPSCS-12L
SPSCS-12V
®
Opt-X
SDX Splice Module
© 2018 Leviton Manufacturing Co., Inc.
Customer Support: 800.824.3005
International: +1.425.486.2222
Web:
www.leviton.com
Installation Instructions
IMPORTANT INSTRUCTIONS
WARNING
Read and understand all instructions. Follow all warning and instructions marked on the product.
Disconnected optical components may emit invisible optical radiation that can damage your eyes. Never look directly into an optical component that may have a laser coupled to it.
Serious and permanent retinal damage is possible. If accidental exposure to laser radiation is suspected, consult a physician for an eye examination.
CAUTIONS
Isopropyl alcohol is flammable, and can cause eye irritation on contact. If eye contact occurs, flush with water for at least 15 minutes. In case of ingestion, consult a physician. Use
only in well ventilated areas.
Wearing safety glasses during installation of this device is recommended. Although standard safety glasses provide no protection from potential optical radiation, they offer protection
from accidental airborne hardware and cleaning solvents.
Fiber optic cable is sensitive to excessive pulling, bending, and crushing forces. Do not bend the cable less than recommended bend radius. Do not use more pulling force on the
cable than specified. Do not kink or crush the cable.
SAVE THESE INSTRUCTIONS.
DESCRIPTION
The Leviton Opt-X SDX Splice Module can accommodate either 12 or 24 single fusion fiber terminations. The module is available in either LC or SC for 12 fiber applications and LC
for 24 fiber applications.
Warning: Always wear eye protection when handling optical fibers. Dispose of any cut or cleaved ends properly.
INSTALLATION
The following installation instructions describe the assembly procedure for the new Opt-X SDX Splice Module which allow for fusion splice termination on 250um, and 900um
fiber/cable.
Patents covering this Product, if any, can be found on Leviton.com/patents
DI-00X-SPLCS-20C

Publicidad

loading

Resumen de contenidos para Leviton Opt-X SPLCS-12A

  • Página 1 SAVE THESE INSTRUCTIONS. DESCRIPTION The Leviton Opt-X SDX Splice Module can accommodate either 12 or 24 single fusion fiber terminations. The module is available in either LC or SC for 12 fiber applications and LC for 24 fiber applications. Warning: Always wear eye protection when handling optical fibers. Dispose of any cut or cleaved ends properly.
  • Página 2 3.0 Tools and supplies required for the installation and required instrument settings and functionality. splicing of the Leviton Opt-X SDX Splice Module will be determined by the installer and as recommended by the 4.1 Install splice sleeves on each trunk fiber leg. Using the fusion splicer manufacture.
  • Página 3 Splice Module Termination (Continued) FIBERS 1-12 4.2 As determined by fiber count, load fibers into the Splice Chips as shown in Figure 8. 4.3 Re-install the trunk cable to the entrance tie down point and secure the service loop as shown in steps 3.7 and 3.8. Provide an additional PIGTAILS tie wrap at the front of the storage as shown in Figure 9.
  • Página 4: Directives Importantes

    CONSERVER LES PRÉSENTES DIRECTIVES. DESCRIPTION Les modules d’épissage Opt-X SDX de Leviton acceptent 12 ou 24 terminaisons simples par fusion. Ils sont offerts en versions LC ou SC (12 fibres) ou encore LC seulement (24 fibres). Avertissement : il faut toujours porter des lunettes de sécurité lorsqu’on manipule des fibres optiques. Les bouts coupés ou clivés doivent en outre être éliminés de la manière appropriée.
  • Página 5 Réenrouler deux boucles de mou dans l’aire de stockage supérieure. Mettre le plateau d’épissage dans la base. Acheminer Méthode d’installation dans un boîtier les fibres de liaison de la manière illustrée à la figure 3, puis au Les modules d’épissage Opt-X SDX sont conçus de façon à centre du support de raccordement.
  • Página 6 FIBERS 1-12 Terminaison du module d’épissage (suite) Selon le nombre de fibres, les insérer dans le support de raccordement de la manière illustrée à la figure 8. PIGTAILS Re-attacher le câble d’artère au point d’entrée et assujettir la boucle de mou de la manière expliquée aux étapes 3.7 et 3.8. Utiliser une attache TRUNK additionnelle à...
  • Página 7: Instrucciones Importantes

    DESCRIPCION El Módulo de Empalme Opt-X SDX de Leviton tiene la capacidad de acomodar fusiones de terminaciones de 12 o 24 fibras sencillas. El módulo está disponible en aplicaciones LC o SC para 12 fibras y LC para aplicaciones de 24.
  • Página 8 Terminación del Módulo de Empalmes 3.0 Las herramientas y suministros requeridos para la instalación y empalme del Módulo de Empalmes Opt-X SDX de Leviton serán determinados por el instalador, de acuerdo a lo recomendado por 4.0 Consulte las instrucciones del fabricante de la empalmadora para los ajustes y funcionalidad requeridos del instrumento.
  • Página 9 FIBERS 1-12 Terminación del Módulo de Empalmes (Continuación) 4.2 De acuerdo a lo determinado por el conteo de fibras, cargue las fibras dentro de los sujetadores de empalmes tal como se muestra en la Figura 8. PIGTAILS 4.3 Instale nuevamente el cable troncal en el punto de sujeción de la entrada y sujete el bucle de servicio tal como se indica en los pasos 3.7 y 3.8. Coloque una TRUNK abrazadera de unión adicional en la parte frontal del almacenamiento tal como se muestra en la Figura 9.