Brizo 75653 Manual Del Usuario página 10

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation and Adjustment of the Temperature Knob
4
Failure to do so may cause injury.
2
1
5
6
RSVP
®
8
7
9
Adjust temperature limit stop! Turn on water
supplies; let the water run at both full hot and full
cold to ensure the water is running as hot/cold
as possible. Place a thermometer in a plastic
tumbler, and hold the tumbler in the water
stream. Place the temperature knob (1) onto the
splines (2), then rotate the temperature knob
until you achieve your maximum desired
temperature from the outlet (not more than 120°
or the lower temperature mandated by your
local plumbing code). Remove the temperature
knob and replace onto the splines (2), making
sure that the temperature knob limit stop (3)
hits against the volume handle limit stop (4)
as shown. Secure the temperature knob using
screw (5) and place cap (6) on knob.
60 Series Maintenance
Faucet leaks from showerhead or tub spout:
SHUT OFF WATER SUPPLIES. Replace Cartridge
Assembly –Repair Kit RP47201.
60 Series Installation
4
Siderna
13
12
®
For RSVP
temperature lever is intended to point upward
near 12 o'clock position. Once desired position
is acquired per instructions above, thread set
screw (7) into handle (8) and secure it to valve
stem by tightening set screw with Allen wrench
(9) provided.
For Siderna
temperature handle (knob) (10) onto valve stem
and secure with screw (11). Ensure O-ring (12) is
assembled on handle cap (13). Install handle cap
by pressing it into place on top of the temperature
handle (10).
If water does not flow:
Verify that the hot side of the cartridge is installed
on the hot water supply line. If
it is not, turn off water supplies and
flip cartridge.
7
®
10
11
(series T60X90) models,
®
(series T60X80) models, place
4
3
1

Publicidad

Tabla de contenido
loading

Productos relacionados para Brizo 75653

Tabla de contenido