General
The range hood is most easily built into a Thermex cooker hood that is custom made for the purpose.
It is recommended that the fitting height of the range hood should be at least 50-60cm over the gas cooker.
NB!
The range hood shall be extra protected cf. the high voltage regulations.
Fitting
1.
Connect the tube to the outlet flange Ø 150mm (fig. 1, A), that should be
installed with collar clip (extra accessory), check that the flaps in the outlet tube
(counter damper) (fig. 1, B) opens and closes.
2.
Make the electrical connection (fig. 2). The range hood is equipped with 1
or 2 leads: TFMH with one lead for the supply source. Besides TFH with 1 lead
for use for external ventilator.
3.
Decide where to place the control panel (fig. 2, A, B):
a. Immediately under the range hood
Then connect the lead from the control box (through the holes in the control panel) to the control
panel and attach it on the triangle.
b. On the outside of the cabinet
Draw the lead out from the range hood and place it where the panel shall
sit (note the length of the lead before making a decision).
Connect the control panel to the lead and attach the control panel in a
flat area that is cleaned thoroughly. Possibly replace the fitting plate with
a cut-out triangle with the enclosed fitting plate. Detach the fitting plate
by removing the 2 finger-screws behind the filters. Move the halogen
spotlights over into the new fitting plate and attach it back into the range
hood.
4.
Fit the range hood (fig. 2) in the opening and only attach it to the cabinet with 4 of the enclosed screws
(there are 8 screws enclosed, which are necessary for the 80cm model).
Outlet to the open air
Access to the open air is established either through the ceiling, wall or outlet duct.
Note:
Never connect the outlet range hood for existing hot air system or chimney.